Practice parameters for the use of autotitrating continuous positive airway pressure devices for titrating pressures and treating adult patients with obstructive sleep apnea syndrome: an update for 2007. An American Academy of Sleep Medicine report.

نویسندگان

  • Timothy I Morgenthaler
  • R Nisha Aurora
  • Terry Brown
  • Rochelle Zak
  • Cathy Alessi
  • Brian Boehlecke
  • Andrew L Chesson
  • Leah Friedman
  • Vishesh Kapur
  • Rama Maganti
  • Judith Owens
  • Jeffrey Pancer
  • Todd J Swick
چکیده

These practice parameters are an update of the previously published recommendations regarding the use of autotitrating positive airway pressure (APAP) devices for titrating pressures and treating adult patients with obstructive sleep apnea syndrome. Continuous positive airway pressure (CPAP) at an effective setting verified by attended polysomnography is a standard treatment for obstructive sleep apnea (OSA). APAP devices change the treatment pressure based on feedback from various patient measures such as airflow, pressure fluctuations, or measures of airway resistance. These devices may aid in the pressure titration process, address possible changes in pressure requirements throughout a given night and from night to night, aid in treatment of OSA when attended CPAP titration has not or cannot be accomplished, or improve patient comfort. A task force of the Standards of Practice Committee of the American Academy of Sleep Medicine has reviewed the literature published since the 2002 practice parameter on the use of APAP. Current recommendations follow: (1) APAP devices are not recommended to diagnose OSA; (2) patients with congestive heart failure, patients with significant lung disease such as chronic obstructive pulmonary disease; patients expected to have nocturnal arterial oxyhemoglobin desaturation due to conditions other than OSA (e.g., obesity hypoventilation syndrome); patients who do not snore (either naturally or as a result of palate surgery); and patients who have central sleep apnea syndromes are not currently candidates for APAP titration or treatment; (3) APAP devices are not currently recommended for split-night titration; (4) certain APAP devices may be used during attended titration with polysomnography to identify a single pressure for use with standard CPAP for treatment of moderate to severe OSA; (5) certain APAP devices may be initiated and used in the self-adjusting mode for unattended treatment of patients with moderate to severe OSA without significant comorbidities (CHF, COPD, central sleep apnea syndromes, or hypoventilation syndromes); (6) certain APAP devices may be used in an unattended way to determine a fixed CPAP treatment pressure for patients with moderate to severe OSA without significant comorbidities (CHF, COPD, central sleep apnea syndromes, or hypoventilation syndromes); (7) patients being treated with fixed CPAP on the basis of APAP titration or being treated with APAP must have close clinical follow-up to determine treatment effectiveness and safety; and (8) a reevaluation and, if necessary, a standard attended CPAP titration should be performed if symptoms do not resolve or the APAP treatment otherwise appears to lack efficacy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Factors Affecting Patients’ Adherence to Continuous Positive Airway Pressure Therapy for Obstructive Sleep Apnea Disorder: A Multi-Method Approach

Background: Continuous positive airway pressure (CPAP) is the gold standard therapy for treating obstructive sleep apnea (OSA) disorder. However, patients’ adherence to its regular use is poor. The present study aimed to determine the adherence rate to CPAP therapy by identifying factors affecting its regular use and its associated problems and discomforts among a sample population in Mashhad (...

متن کامل

The use of auto-titrating continuous positive airway pressure for treatment of adult obstructive sleep apnea. An American Academy of Sleep Medicine review.

This paper reviews the efficacy of auto-titrating continuous positive airway pressure (APAP) for treatment of obstructive sleep apnea. It is based on a review of 30 articles published in peer review journals conducted by a task force appointed by the American Academy of Sleep Medicine to develop practice parameters for use of APAP devices for treatment of obstructive sleep apnea (OSA). The data...

متن کامل

Hypersensitivity pneumonitis due to metalworking fluid exposures.

1. Toyama Y , Chin K , Chihara Y , et al . Association between sleep apnea, sleep duration, and serum lipid profi le in an urban, male, working population in Japan . Chest . 2013 ; 143 ( 3 ): 720 728 . 2. Sharma SK , Agrawal S , Damodaran D , et al . CPAP for the metabolic syndrome in patients with obstructive sleep apnea . N Engl J Med . 2011 ; 365 ( 24 ): 2277 2286 . 3. Nakayama-Ashida Y , Ta...

متن کامل

Practice parameters for the use of continuous and bilevel positive airway pressure devices to treat adult patients with sleep-related breathing disorders.

Positive airway pressure (PAP) devices are used to treat patients with sleep related breathing disorders (SRBD) including obstructive sleep apnea (OSA). Currently, PAP devices come in three forms: (1) continuous positive airway pressure (CPAP), (2) bilevel positive airway pressure (BPAP), and (3) automatic self-adjusting positive airway pressure (APAP). After a patient is diagnosed with OSA, th...

متن کامل

Interventions to improve compliance in sleep apnea patients previously non-compliant with continuous positive airway pressure.

STUDY OBJECTIVES Despite widespread agreement that continuous positive airway pressure is effective therapy for obstructive sleep apnea, it is estimated that 50% of patients recommended for therapy are noncompliant 1 year later. Interventions to improve compliance in such patients have not been studied. We evaluated a 2 phase intervention program to improve compliance in sleep apnea patients pr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Sleep

دوره 31 1  شماره 

صفحات  -

تاریخ انتشار 2008