Bioimpedance cardiography measurements of cardiac output and other cardiovascular parameters.

نویسنده

  • Nancy M Albert
چکیده

This paper describes impedance technique and device types, discusses hemodynamic data parameters that are available, discusses the differences between impedance cardiography and data that are derived from invasive pulmonary artery catheters, and explains how nurses can apply bioimpedance cardiography in a variety of patient populations.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bioimpedance cardiography in pregnancy: A longitudinal cohort study on hemodynamic pattern and outcome

BACKGROUND Pregnancy associated cardiovascular pathologies have a significant impact on outcome for mother and child. Bioimpedance cardiography may provide additional outcome-relevant information early in pregnancy and may also be used as a predictive instrument for pregnancy-associated diseases. METHODS We performed a prospective longitudinal cohort trial in an outpatient setting and include...

متن کامل

Assessment of beat to beat changes in cardiac output during the Valsalva manoeuvre using electrical bioimpedance cardiography.

Beat to beat changes in cardiac output during standardized Valsalva's manoeuvres were recorded using electrical bioimpedance cardiography in 13 normal subjects. Cardiac output increased by 12 +/- 5% after 1 s of straining solely because of an increase in heart rate. Subsequently, cardiac stroke volume and cardiac output fell during the strain to lows of -40 +/- 6% and -21 +/- 3% respectively at...

متن کامل

Denoising of Radial Bioimpedance Signals using Adaptive Wavelet Packet Transform and Kalman Filter

In recent years, the accurate computer aided diagnosis of the cardiovascular diseases is gaining momentum. In addition to accuracy, non-invasiveness of the measurement techniques has become the need of the hour. Impedance cardiography is one such method which has become a synonym for indirect assessment of monitoring the stroke volume, cardiac output and other hemodynamic parameters by monitori...

متن کامل

Measurement of Cardiac Output using Bioimpedance Methd

Cardiac output (CO), in conjunction with hemoglobin concentration and arterial oxygen saturation are the cornerstones of oxygen transport. Cardiac output is the functional expression of cardiovascular performance and can be used to confirm the need for, or usefulness of treatment. Determination of cardiac output is an important procedure in interventional cardiology and also used in cardiothora...

متن کامل

Automated non-invasive measurement of cardiac output: comparison of electrical bioimpedance and carbon dioxide rebreathing techniques.

Two commercial automated, non-invasive systems for estimation of cardiac output were evaluated. Values of cardiac output obtained by electrical bioimpedance cardiography (BoMed NCCOM3 machine) were compared with values derived from an indirect Fick technique that uses carbon dioxide rebreathing (Gould 9000 IV system) during 103 simultaneous measurements made at rest in 19 randomly selected subj...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Critical care nursing clinics of North America

دوره 18 2  شماره 

صفحات  -

تاریخ انتشار 2006