The CLEO-III Trigger: Analog and Digital Calorimetry1
نویسندگان
چکیده
The calorimetry subsystem of the CLEO-III Trigger incorporates both analog and digital electronics to provide pipelined trigger information every 42 ns with a latency of approximately 2.5 μs. This paper describes the pipelined signal-processing and pattern-recognition schemes used to provide calorimeter information to the experiment trigger, with somewhat greater emphasis on the analog components of the system. Analog processing is employed to address the quantization error caused by split energy deposition in adjacent calorimeter cells, and digital field programmable gate arrays are used extensively to filter and categorize the calorimeter energy topology. Timing, geographical, and energy information are all available for use in the calorimeter trigger.
منابع مشابه
The CLEO-III Trigger: Axial and Stereo Tracking1
The tracking subsystem of the CLEO-III Trigger consists of separate axial and stereo tracking pattern-matching modules, whose products are time-aligned and spatially correlated to provide pipelined trigger information every 42 ns with a latency of approximately 2 μs. This paper describes the pipelined signal processing and pattern recognition schemes used by the axial and stereo electronics to ...
متن کاملImproving adaptive resolution of analog to digital converters using least squares mean method
This paper presents an adaptive digital resolution improvement method for extrapolating and recursive analog-to-digital converters (ADCs). The presented adaptively enhanced ADC (AE-ADC) digitally estimates the digital equivalent of the input signal by utilizing an adaptive digital filter (ADF). The least mean squares (LMS) algorithm also determines the coefficients of the ADF block. In this sch...
متن کاملThe CLEO-III Trigger: Design Methodology Case Study1
The design of the CLEO-III Trigger produced 24 different multilayer printed circuit board designs, and over 100 FPGA configurations. Only one board design was intentionally prototyped and respun; only one board design was respun due to design/layout error; only one board design had more than 6 ECO wires. A detailed case study of the CLEO-III Trigger design methodology is presented. Scheduling, ...
متن کاملThe CLEO-III Trigger: Level 1 Decision and Gating1
The Level 1 Decision and Data Flow/Control subsystems of the CLEO-III Trigger produce and distribute a trigger decision every 42 ns based on input from calorimetry and tracking subsystems. This paper describes the free-running pipelined trigger decision logic that correlates axial and stereo tracking information, and combines time-aligned calorimetry information onto a common backplane. Program...
متن کاملTrigger Development for Two-Photon Physics at CLEO III
The goal of this study was to develop trigger requirements to facilitate the detection of twophoton interactions producing c and f 0 2 mesons while minimizing the overall trigger rate of the CLEO III detector. Monte Carlo simulations of data were analyzed and a trigger simulation was created. Separate triggers were developed for decays producing charged daughters (e.g., kaons or pions) and deca...