Imposing Differential Constraints on Radial Distortion Correction
نویسندگان
چکیده
Many radial distortion functions have been presented to describe the mappings caused by radial lens distortions in common commercially available cameras. For a given real camera, no matter what function is selected, its innate mapping of radial distortion is smooth, and the signs of its first and second order derivatives are fixed. However, such differential constraints have been never considered explicitly in existing methods of radial distortion correction for a very long time. The differential constraints we claimed in this paper are that for a given real camera, the signs of the first and second order derivatives of the radial distortion function should remain unchanged within the feasible domain of the independent variable, although over the whole domain, or outside of the feasible domain, the signs may change many times. Our method can be somewhat treated as a regularization of the distortion function within the viewing frustum. We relax the differential constraints by using a deliberate strategy, to yield the linear inequality constraints on the unknown coefficients of the radial distortion function. It seems that such additional linear inequalities are not difficult to deal with in recent existing methods of radial distortion correction. The main advantages of our method are not only to ensure the recovered radial distortion function satisfy differential constraints within the viewing frustum, but also to make the recovered radial distortion function working well in case of extrapolation, caused by the features used for distortion correction usually distributed only in the middle part, but rarely near the boundary of the distorted image. The experiments validate our approach.
منابع مشابه
The Iterative Method of Parameters and Centre of Radial Distortion Estimation
Correction of radial distortion of the image is a very important process during the calibration of non-metric camera intrinsic parameters. The paper treats the topic of estimation of coefficients and the centre of radial distortion of the image. A new method of coefficients and coordinates of the centre of radial distortion estimation in the image is presented. It is based on the iterative corr...
متن کاملNonparametric , Model - Based Radial Lens Distortion Correction Using Tilted Camera Assumption ∗
Radial lens distortion prohibits use of simple pinhole camera models in computer vision applications, especially when using wide-angle lenses, which result in barreltype distortion. Usual approach to radial distortion is by the means of polynomial approximation, which introduces distortion-specific parameters into the camera model and requires iterative methods for their calculation. Based on t...
متن کاملImproving Accuracy of DGPS Correction Prediction in Position Domain using Radial Basis Function Neural Network Trained by PSO Algorithm
Differential Global Positioning System (DGPS) provides differential corrections for a GPS receiver in order to improve the navigation solution accuracy. DGPS position signals are accurate, but very slow updates. Improving DGPS corrections prediction accuracy has received considerable attention in past decades. In this research work, the Neural Network (NN) based on the Gaussian Radial Basis Fun...
متن کاملAccurate Camera Calibration and Correction Using Rigidity and Radial Alignment Constraints
In this paper, we develop a novel method for camera calibration and correction. The novel method first employs a rigidity constraint from the rigid rotation matrix and the radial alignment constraint from the pin-hole camera model to estimate both camera intrinsic and extrinsic parameters with a closed-form solution without considering the camera distortion. Then the well-known Levernburg-Marqu...
متن کاملNew approach for calibration of pixelated scintillation detectors of intraoperative gamma cameras
Introduction:SURGEOSIGHT is a dedicated intra-operative hand-held gamma camera designed and manufactured by our team to be used for lymphoscintigraphy. Although conventional gamma cameras are widely used, they lack the capability of the sentinel lymph node (SLN) imaging in the operation room. Like conventional gamma cameras it is necessary to calibrate SURGEOSIGHT for linearity...
متن کامل