Experimental biomechanical assessment of plate stabilizers for treatment of pectus excavatum.

نویسندگان

  • Anita Kajzer
  • Wojciech Kajzer
  • Bożena Gzik-Zroska
  • Wojciech Wolański
  • Irena Janicka
  • Józef Dzielicki
چکیده

The paper discusses results of experimental research involving new generation of plate stabilizers used for the treatment of deformation of the front chest wall. Previous clinical monitoring revealed instances of minimal rotation, which caused destabilization of the anastomosis and pain in patients. In order to prevent this, transverse stabilizing plates were introduced to the structure of the stabilizer. The new structure of stabilizers was tested using two specially prepared research posts: 1 - which enables fastening of the plate stabilizers to a platform simulating human ribs, 2 - using a pig chest, to which plates were fastened according to the stabilization conditions in the stabilizer-chest structure. The tests recorded displacement values in selected areas of the plates in response to applied loading forces.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

First Iranian Experience of the Minimally Invasive Nuss Procedure for Pectus Excavatum Repair: A Case Series and Literature Review

Pectus excavatum is the most common congenital deformity of the chest wall. The most frequently used techniques include Ravitch (costochondral resection) and Nuss (minimally invasive pectus repair of pectus excavatum [MIRPE]). The Nuss technique includes using temporary metallic bars without costochondral resection to correct the chest wall deformity. Modified MIRPE can be learned easily and pe...

متن کامل

Effects of Pectus Excavatum on the Spine of Pectus Excavatum Patients with Scoliosis

BACKGROUND There is high risk in the correction surgery of pectus excavatum with scoliosis because of the lack of the correction mechanism of pectus excavatum with scoliosis. This study performed a comprehensive analysis about the impact that pectus excavatum had on scoliosis and elaborated its biomechanical mechanism in pectus excavatum patients with scoliosis. METHODS 37 pectus excavatum pa...

متن کامل

Experience and modification update for the minimally invasive Nuss technique for pectus excavatum repair in 303 patients.

PURPOSE The aim of this study is to review the new technical modifications and results of 303 patients who have had pectus excavatum repair utilizing the minimally invasive technique. METHODS A retrospective chart review was conducted of 303 patients undergoing minimally invasive pectus repair from 1987 through August 2000. Since 1997, a standardized treatment pathway was implemented, and 261...

متن کامل

Use of a subxiphoid incision for pectus bar placement in the repair of pectus excavatum.

BACKGROUND Since the first description of the Nuss repair for pectus excavatum, many technical variations have been described. Over the past 10 years, we have used a subxiphoid incision to allow finger guidance to protect the mediastinum which obviates the need for thoracoscopy. METHODS A retrospective review was conducted on all our patients who have undergone pectus excavatum repair from De...

متن کامل

Orthopedic Approach to Pectus Deformities: 32 Years of Studies.

The authors summarize a 32-year experience in the study and in the non-operative approach of pectus carinatum and pectus excavatum. Data of 4,012 patients with pectus deformities were collected from 1977 to January 2009, allowing evaluation on the etiology, pathogenesis and treatment of these deformities. Growth disturbances of anterior chest wall bones and cartilages were detected in imaging s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Acta of bioengineering and biomechanics

دوره 15 3  شماره 

صفحات  -

تاریخ انتشار 2013