Radiation safety issues with positron‐emission/computed tomography simulation for stereotactic body radiation therapy
نویسندگان
چکیده
Stereotactic body radiation therapy (SBRT) simulations using a Stereotactic Body Frame (SBF: Elekta, Stockholm, Sweden) were expanded to include 18F-deoxyglucosone positron-emission tomography (FDG PET) for treatment planning. Because of the length of time that staff members are in close proximity to the patient, concerns arose over the radiation safety issues associated with these simulations. The present study examines the radiation exposures of the staff performing SBRT simulations, and provides some guidance on limiting staff exposure during these simulations. Fifteen patients were simulated with PET/CT using the SBF. Patients were immobilized in the SBF before the FDG was administered. The patients were removed from the frame, injected with FDG, and allowed to uptake for approximately 45 minutes. After uptake, the patients were repositioned in the SBF. During the repositioning, exposure rates were recorded at the patient's surface, at the SBF surface, and at 15 cm, 30 cm, and 1 m from the SBF. Administered dose and the approximate time spent on patient repositioning were also recorded. The estimated dose to staff was compared with the dose to staff performing conventional diagnostic PET studies. The average length of time spent in close proximity (<50 cm) to the patient after injection was 11.7 minutes, or more than twice the length of time reported for diagnostic PET staff. That time yielded an estimated average dose to the staff of 26.5 microSv per simulation. The annual occupational exposure limit is 50 mSv. Based on dose per simulation, staff would have to perform nearly 1900 SBRT simulations annually to exceed the occupational limit. Therefore, at the current rate of 50-100 simulations annually, the addition of PET studies to SBRT simulations is safe for our staff. However, ALARA ("as low as reasonably achievable") principles still require some radiation safety considerations during SBRT simulations. The PET/CT-based SBRT simulations are safe and important for treatment planning that optimizes biologic dose distribution with highly accurate and reproducible target definition.
منابع مشابه
2-[18F]Fluoro-2-Deoxy-D-Glucose Positron Emission Tomography Definition of Lung Targets in Vero Stereotactic Body Radiation Therapy Workflow
This retrospective study explored 2-[18F]fluoro-2-deoxy-D-glucose positron emission tomography (FDG-PET) as an aid in target delineation among a first-group of five patients with single or multiple moving lung tumors planned for Vero stereotactic body radiation therapy (SBRT). Computed tomography (CT)-based free-breathing, end-inspiration, and end-expiration lung target volumes generated a sing...
متن کاملA Novel Method to Evaluate Local Recurrence of Lung SBRT using Follow-up PET Although the method utilizing the maximum standard uptake value (SUVmax) 18F-FDG Positron Emission Tomography (PET) to assess the outcome of lung stereotactic body radiotherapy
Although the method utilizing the maximum standard uptake value (SUVmax) 18F-FDG Positron Emission Tomography (PET) to assess the outcome of lung stereotactic body radiotherapy (SBRT) has been widely accepted in practice, its reliability has frequently been challenged i . The purpose of this study is to explore and test a novel method using a self background-corrected SUVmax (cSUVmax) in detect...
متن کاملDynamic Lung Tumor Tracking for Stereotactic Ablative Body Radiation Therapy
Physicians considering stereotactic ablative body radiation therapy (SBRT) for the treatment of extracranial cancer targets must be aware of the sizeable risks for normal tissue injury and the hazards of physical tumor miss. A first-of-its-kind SBRT platform achieves high-precision ablative radiation treatment through a combination of versatile real-time imaging solutions and sophisticated tumo...
متن کاملImpact of pretreatment whole-tumor perfusion computed tomography and 18F-fluorodeoxyglucose positron emission tomography/computed tomography measurements on local control of non–small cell lung cancer treated with stereotactic body radiotherapy
This study aimed to investigate the correlation between the average iodine density (AID) detected by dual-energy computed tomography (DE-CT) and the maximum standardized uptake value (SUVmax) yielded by [18F] fluorodeoxyglucose positron emission tomography (18F-FDG PET) for non-small cell lung cancer (NSCLC) treated with stereotactic body radiotherapy (SBRT). Seventy-four patients with medicall...
متن کاملA case of radiotherapy for an advanced bronchial carcinoma patient with implanted cardiac rhythm machines as well as heart assist device
We present a case of radiotherapy for a 66-year-old patient with squamous cell carcinoma on the left main bronchus undergoing implantation of pacemaker, implantable cardioverter defibrillator (ICD) as well as cardiopulmonary support (CPS) device. The radiation area was determined according to 4D List Mode positron emission tomography-computed tomography (PET-CT) data. Planning Target Volume (PT...
متن کامل