Ultra-fast liquid chromatography with a photodiode array detector for simple and rapid determination of urea in body fluids of farm animals is described. Blood plasma, milk, and urine samples are treated with trichloroacetic acid and then centrifuged. Supernatants are derivatized at room temperature using p-dimethylaminobenzaldehyde. Samples are separated using a ternary gradient of methanol in buffer and water. Derivatized urea in standards and biological samples is analyzed using a Phenomenex C18-column (Synergi 2.5 μm, Hydro-RP, 100Å, 100 × 2 mm). The photodiode detector is set to 370 and/or 254 nm for detection. Temperature is maintained at 27°C by a column heater. Clear separation of derivatized urea from the endogenous species present in assayed biological samples was achieved in less than 6 min. The urea adduct peak eluted at 4.36 ± 0.05 min. Average recoveries of the urea standards added to assayed biological materials were satisfactory (i.e. 100.2 ± 4.1%). Our chromatographic method with photodiode detection at 370 nm and at 254 nm, in particular, offers low detection (LD) and quantification limits (LQ) ( LD = 0.47 ng, LD = 0.027 ng and LQ = 1.41 ng, LQ = 0.080 ng, respectively). Our liquid chromatography based on detection at 370 nm is the most versatile analytical tool that assures sensitive, accurate, and precise analysis of urea in urine, milk, and plasma samples, and selected diets for mammals. The presented chromatographic procedure is especially suitable for preparation of reference sample sets, very accurate and precise research purposes or rapid clinical diagnostic with smaller sample sets. Urea in urine can be also determined using our liquid chromatography with detection at 254 nm. Detection of urine urea at 254 nm is more sensitive and precise compared with monitoring at 370 nm. Our chromatographic method based on photodiode detection at 370 nm and especially at 254 nm is suitable for the non-invasive analysis of urea in only urine of humans and animals.
منابع مشابه
A simple, sensitive and rapid isocratic reversed-phase high-performance liquid chromatography method for determination and stability study of curcumin in pharmaceutical samples
Objective: This study was designed to develop and validate a new reversed-phase high-performance liquid chromatography (RP-HPLC) method based on Q2 (R1) International Conference on Harmonization (ICH) guideline for determination of curcumin in pharmaceutical samples. Materials and Methods: The HPLC instrument method was optimized with isocratic elution with acetonitrile: ammonium acetate (45:55...
متن کاملSensitive Simultaneous Measurement of Metformin and Linagliptin in Plasma Samples by Couple of Nano Graphene Oxide-based Dispersive Solid Phase Extraction Method and Liquid Chromatography
A simple, rapid, and ultra sensitive dispersive solid phase extraction based on nano graphene oxide was developed for simultaneous measurement of trace amounts of metformin (MET) and linagliptin (LIN) in plasma samples by HPLC-UV-Vis. Affecting factors on the extraction of these drugs, including adsorbent weight, extraction time, organic solvent type, desorption situations, and composition of s...
متن کاملSimultaneous Determination of Six Benzodiazepines in Spiked Soft Drinks by High Performance Liquid Chromatography with Ultra Violet Detection (HPLC-UV)
A high performance liquid chromatographic method with ultra violet detection for simultaneous analysis of six benzodiazepines (BZDs) (chlordiazepoxide, diazepam, clonazepam, midazolam , flurazpam and lorazepam) has been developed for forensic screening of adulterated non-alcoholic drinks. Samples were analyzed after a simple procedure for preparation using pH adjustment and filtering. Isocratic...
متن کاملSimultaneous Determination of Six Benzodiazepines in Spiked Soft Drinks by High Performance Liquid Chromatography with Ultra Violet Detection (HPLC-UV)
A high performance liquid chromatographic method with ultra violet detection for simultaneous analysis of six benzodiazepines (BZDs) (chlordiazepoxide, diazepam, clonazepam, midazolam , flurazpam and lorazepam) has been developed for forensic screening of adulterated non-alcoholic drinks. Samples were analyzed after a simple procedure for preparation using pH adjustment and filtering. Isocratic...
متن کاملSensitive Simultaneous Measurement of Metformin and Linagliptin in Plasma Samples by Couple of Nano Graphene Oxide-based Dispersive Solid Phase Extraction Method and Liquid Chromatography
A simple, rapid, and ultra sensitive dispersive solid phase extraction based on nano graphene oxide was developed for simultaneous measurement of trace amounts of metformin (MET) and linagliptin (LIN) in plasma samples by HPLC-UV-Vis. Affecting factors on the extraction of these drugs, including adsorbent weight, extraction time, organic solvent type, desorption situations, and composition of s...
متن کامل