BACKGROUND The outcome of patients with severe ischaemic left ventricular (LV) dysfunction is determined by the extent of myocardial viability and the presence of LV dyssynchrony. We aimed at assessing both parameters from the same imaging method, i.e. gated positron emission tomography (PET) F18-fluorodeoxyglucose (FDG) scans. METHODS Phase analysis from Emory Cardiac Toolbox was applied on gated PET-FDG scans to assess histogram bandwidth and standard deviation (SD) as a measure of LV dyssynchrony in 30 heart failure patients (mean ejection fraction: 30.2% ± 13.8%) referred for the evaluation of myocardial viability. Cut-off values from single-photon emission computed tomography myocardial perfusion imaging (SPECT-MPI) best predicting cardiac resynchronization therapy (CRT) response served as standard of reference (bandwidth < 135°; phase SD < 43°). Severe LV dyssynchrony was diagnosed if both SPECT-MPI values were above these limits. Intraclass correlation and clinical agreement in detection of severe LV dyssynchrony by PET vs SPECT were assessed. RESULTS There was a significant correlation between PET-FDG and SPECT-MPI for bandwidth (r = 0.88, P < .001) and phase SD (r = 0.88, P < .001) resulting in an excellent clinical agreement between the two methods of 93%. CONCLUSIONS Accurate LV dyssynchrony assessment by phase analysis of gated PET-FDG scans is feasible, allowing assessing myocardial viability and severe LV dyssynchrony in one scan.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impact of Phase Analysis of Gated SPECT to Assessment of Left Ventricular Mechanical Dyssynchrony in Diabetic Patients with Normal MPI

Objective: Diabetes mellitus is an important cause of heart failure deployment of left ventricular mechanical dyssynchrony. Nuclear cardiology phase analysis is an accurate, repeatable and reproducible modality for measurement LV dyssynchrony .The aim of study was assessment of phase analysis parameter including Standard deviation (SD) and band width (BW) in diabetic patient with normal MPI com...

متن کامل

Evaluation of the potential impact of reconstruction method on dyssynchrony parameters derived by phase analysis of gated-SPECT MPI: Comparison of two quantitative software

Introduction: Gated SPECT myocardial perfusion scanning has new capabilities in addition to its main applications such as left ventricular dyssynchrony using phase analysis. Phase analysis has been investigated through various software including Emory Cardiac Toolbox (ECTb) and Quantitative Gated SPECT (QGS). The aim of this study is to evaluate the effect of reconstruction par...

متن کامل

Gated cardiac 13N-NH3 PET for assessment of left ventricular volumes, mass, and ejection fraction: comparison with electrocardiography-gated 18F-FDG PET.

UNLABELLED The purpose of this study was to evaluate myocardial electrocardiography (ECG)-gated 13N-ammonia (13N-NH3) PET for the assessment of cardiac end-diastolic volume (EDV), cardiac end-systolic volume (ESV), left ventricular (LV) myocardial mass (LVMM), and LV ejection fraction (LVEF) with gated 18F-FDG PET as a reference method. METHODS ECG-gated 13N-NH3 and 18F-FDG scans were perform...

متن کامل

Determination of normal ranges of regional and global phase parameters using gated myocardial perfusion imaging with Cedars-Sinai’s QGS software

Introduction: Myocardial perfusion imaging using gated SPECT and phase analysis is an effective tool in evaluation of mechanical dyssynchrony. The purpose of this study was to determine the normal ranges of global and regional phase parameters. Methods: A total of 100 patients with normal resting and stress electrocardiograms, low pretest likelihood for c...

متن کامل

Left Ventricular Dyssynchrony Parameters Measured by Phase Analysis of Post-stress and Resting Gated SPECT Myocardial Perfusion Imaging

Phase analysis has been validated to measure left ventricular (LV) dyssynchrony from resting gated SPECT myocardial perfusion imaging (MPI). In 1-day rest/stress protocols, often only post-stress gated data are acquired. The purpose of this study was to determine whether LV dyssynchrony parameters measured at post-stress significantly differ from those measured at rest. Sixty normal subjects, 4...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology

دوره 18 5  شماره 

صفحات  -

تاریخ انتشار 2011