The efficacy of Tc-99m sestamibi for sentinel node mapping in breast carcinomas: comparison with Tc-99m antimony sulphide colloid.
نویسندگان
چکیده
BACKGROUND To study the value of periareolar intra-dermal injection of Tc-99m sestamibi (MIBI) for sentinel node mapping in breast carcinoma. MATERIAL AND METHODS Fifty patients with early-stage breast cancer were included in our study. 17.5 MBq Tc-99m-MIBI was injected intradermally to 25 patients and the remainders were injected with the same dose of Tc-99m-antimony sulphide colloid. Anterior and lateral static images were taken at 2 minutes. If sentinel lymph node was not detected, delayed imaging by up to 180 minutes was carried out. The patients were operated on 2-4 hours post-injection. Sentinel lymph node biopsy was performed by the aid of gamma probe and blue dye during surgery. RESULTS In the Tc-99m-MIBI group, 23 patients had lymph nodes on scintigraphy images, and sentinel nodes were detected during surgery in all 23 patients. In the Tc-99m-antimony sulphide colloid group, 24 patients had lymph nodes on scintigraphy images, and sentinel nodes were identified during surgery in 24 patients. CONCLUSIONS We concluded that 99mTc-MIBI is a suitable radiopharmaceutical for sentinel node detection.
منابع مشابه
Sentinel node detection failure due to defective labeling and large particle size of Tc-99m antimony sulfide colloid
Introduction: Many radiotracers have been used for sentinel node mapping with acceptable results. The main difference between these radiotracers is the particle size. In the current study, we reported defective labeling of Tc-99m antimony sulfide colloid which resulted in large particle size. Methods: Tc-99m-Antimony sulfide colloid was used for axillary sentinel n...
متن کاملSentinel lymph node biopsy in melanoma patients: An experience with Tc-99m antimony sulfide colloid
Introduction: Sentinel lymph node biopsy is the standard procedure for lymph node staging in intermediate thickness melanoma. In Iran, this procedure has not been addressed sufficiently. In this study, we report our experience in this area. Methods: Ten consecutive patients with intermediate thickness melanoma where included in our study. 1.5 mCi of Tc-99m antimony...
متن کاملBody outlining using Tc-99m filled flood source for lymphoscintigraphy imaging
Introduction: In the current study, we evaluated the feasibility of body outlining using Tc-99m filled flood source for lymphoscintigraphy imaging. Methods: 80 patients were included in the study. Sentinel node mapping was done using Tc-99m Antimony sulfide colloid. For outlining the body a Tc-99m filled flood source was used which was placed behind or lateral to t...
متن کاملSentinel node mapping for early breast cancer patients using 99mTc-phytate: Single center experience on 165 patients
Introduction: Several radiotracers are being used for sentinel node mapping in patients with breast cancer. In the current study, we reported our experience with 99m-Tc Phytate for sentinel node mapping in Mashhad University of Medical Sciences. Methods: All breast cancer patients who underwent sentinel node mapping using 99m-Tc Phytate were included. All patients received intradermal peri-are...
متن کاملSentinel node detection failure due to defective labeling and large particle size of Tc - 99 m antimony sulfide colloid
Introduction: Many radiotracers have been used for sentinel node mapping with acceptable results. The main difference between these radiotracers is the particle size. In the current study, we reported defective labeling of Tc-99m antimony sulfide colloid which resulted in large particle size. Methods: Tc-99m-Antimony sulfide colloid was used for axillary sentinel node mapping of 45 breast cance...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Nuclear medicine review. Central & Eastern Europe
دوره 13 1 شماره
صفحات -
تاریخ انتشار 2010