Post-chemiluminescence phenomenon of NBS-luminol reactions and their applications to flow injection analysis of piroxicam.
نویسندگان
چکیده
A new post-chemiluminescence (PCL) reaction was observed when piroxicam was injected into the reaction mixture after the CL reaction of N-bromosuccinimide (NBS) and luminol. A possible reaction mechanism was proposed based on the studies of the CL kinetic characteristics, the CL spectra, fluorescence spectra and other experiments. A new flow injection CL method for the determination of piroxicam was established based on the PCL reaction. The relative standard deviation (RSD) for the determination of piroxicam was 1.2% (n = 11, c = 2.0 x 10(-6) g/ml). The CL intensity responded linearly to the concentration of piroxicam in the range 1.0 x 10(-7) - 1.0 x 10(-5) g/ml (r = 0.9991). The detection limit was 4.0 x 10(-8) g/ml. The method had been applied to the determination of piroxicam in tablets with satisfactory results.
منابع مشابه
Chemiluminescence Determination of Atropine using Luminol-Hemin-H2O2 System
A sensitive and fast chemiluminescence (CL) method has been described for the direct determination of atropine. The method is based on the quenching effect of atropine on the CL signals of the luminol– H2O2 reaction catalyzed by hemin in an alkaline medium. Hemin could strongly enhance the chemiluminescence of the luminol–H2O2 system. The luminophor of the luminol–H2O2–hemin CL system was ident...
متن کاملPostcolumn chemiluminescence as a detection technique in the liquid chromatographic analysis of beta-lactam ring containing compounds.
A broad range of compounds containing the beta-lactam ring were screened for enhancement of luminol chemiluminescence. A selection of these compounds were found to enhance the chemiluminescence of luminol. A high-performance liquid chromatographic method for the analysis of some beta-lactams employing postcolumn chemiluminescence was developed via flow injection analysis studies.
متن کاملChemiluminescence Determination of Some Fluoroquinolones Using NBS-Luminol System
A new, simple, rapid and sensitive batch chemiluminescence (CL) method for determination of six fluoroquinolones (ciprofloxacin, gatifloxacin, levofloxacin, lomefloxacin HCl, ofloxacin and sparfloxacin) is proposd. The method is based on the CL generated during the oxidation of luminol by N-bromosuccinimide (NBS) in alkaline medium. The determination of the studied drugs is based on their inhib...
متن کاملA Fully Automated Sequential-Injection Analyser for Dual Electrogenerated Chemiluminescence/Amperometric Detection
This work describes the development of a dedicated, fully automated sequential-injection analysis (SIA) apparatus suitable for simultaneous electrogenerated chemiluminescence (ECL) and amperometric detection. The instrument is composed of a peristaltic pump, a multiposition selection valve, a home-made potentiostat, a thin-layer electrochemical/optical flow-through cell, and a light detector. C...
متن کاملStudy of the effects of CO2(g) on the Fe(II)-luminol chemiluminescence system: application to ultra-trace analysis of Fe(II)
The Fe(II)-catalyzed oxidation of luminol has been a well-accepted chemiluminescence method for the trace and ultra-trace analysis of Fe(II) and Fe(III) in natural waters. Investigation into this chemiluminescence system has shown that COlg) is essential to Fe-catalyzed luminol chemiluminescence. In absence of CO2(g) there is no chemiluminescent signal. These reactions worked well in the past b...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical sciences : the international journal of the Japan Society for Analytical Chemistry
دوره 23 11 شماره
صفحات -
تاریخ انتشار 2007