Experimental Investigation of Evaporative Heat Transfer Characteristics for R-22 and R-407C Using Thermochromic Liquid Crystal
نویسندگان
چکیده
Evaporative heat transfer coefficients of R~22 and R-407C (R-32/125/134a, 23/25/52 wt%) in a horizontal smooth tube have been measured. Heat was transferred to theJefrigerant at the test section by applying electric current directly to the stainless steel tube. Saturation temperature of refrigerant was calculated from the measured pressure. The inner wall temperatures were calculated by one dimensional heat conduction equation from the measured outer wall temperatures by an imaging technique using thermochromic liquid crystal (TLC). The RGB values of TLC were calibrated by neural network theory. Experiments were conducted for heat flux of 3.6 kW/m, mass flux from 100 kg/ms to 300 kg/ms, and quality from 0.1 to 0.7. Results show circumferential variation of heat transfer coefficients for R-22 was greater than that for R-407C.
منابع مشابه
Evaluation of Evaporative Cooling for Heat Transfer in the Condenser of Window-Air Conditioners
There is a demand for reduced power consumption in the vapor compression refrigeration cycle. Coefficient of performance of window-air conditioners considerably decreases and power consumption increases under very hot conditions. These problems have encouragecl studies aimed at improving the performance of window-air-conditioners by enhancing the heat transfer rate in the condenser. In this ar...
متن کاملEvaluation of Evaporative Cooling for Heat Transfer in the Condenser of Window-Air Conditioners
There is a demand for reduced power consumption in the vapor compression refrigeration cycle. Coefficient of performance of window-air conditioners considerably decreases and power consumption increases under very hot conditions. These problems have encouragecl studies aimed at improving the performance of window-air-conditioners by enhancing the heat transfer rate in the condenser. In this ar...
متن کاملOptimized heat transfer correlations for pure and blended refrigerants
Refrigerant blends and pure refrigerants have wide applicability in thermal engineering. One of the critical parameters in the design and evaluation of thermal equipment is the heat transfer coefficient, which can be difficult to determine for refrigerants that undergo phase change within the equipment. For pure refrigerants, classical experimental relations developed by Gungor and Winterton (G...
متن کاملComparison of R-407C AND R-410A with R-22 in a 10
The performance of two long term replacements R-407C (HFC-32/125/134a (23%/25%/52%)) and R-410A (HFC-32/125 (50%/50%)) was compared to R-22 in a 10.5 kW (3.0 TR) residential central heat pump. The performance evaluations were carried out in a psychrometric calorimeter test facility located at NRC using the Canadian Standards Association (GSA) I Air-Conditioning and Refrigeration Institute (ARI)...
متن کاملPost-CHF heat transfer during two-phase upflow boiling of R-407C in a vertical pipe
1359-4311/$ see front matter 2009 Elsevier Ltd. A doi:10.1016/j.applthermaleng.2009.07.016 * Corresponding author. Tel.: +91 4422574680; fax E-mail address: [email protected] (A.R. Balakrishna This paper reports a study of heat transfer in the post-critical heat flux (post-CHF) regime under forced convective upflow conditions in a uniformly heated vertical tube of 12.7 mm internal diameter and ...
متن کامل