Frequency domain model for transient analysis of lightning protection systems of buildings
نویسنده
چکیده
A frequency domain modeling approach for lightning protection systems (LPS) of buildings is described and validated in this paper. The model is based on a 2-port transmission line representation of each conductor, and the further assembling of a network representing the complete structure. Horizontal and vertical conductors are modeled using formulas based on the complex images method, in order to take into account frequency dependence. Variation of electrical parameters with height is also considered for vertical conductors. This is accomplished by means of a non-uniform modeling approach based on conductor subdivision and cascaded connection of chain matrices computed for each segment. The results from the model are validated by means of comparisons with measurements reported elsewhere, as well as simulations using PSCAD/EMTDC.
منابع مشابه
Application of Intelligent Water Drops in Transient Analysis of Single Conductor Overhead Lines Terminated to Grid-Grounded Arrester under Direct Lightning Strikes
In this paper, Intelligent water drop algorithm (IWD) is used to analyze single overhead line connected to grid-grounded arrester. In this approach, at first Norton’s equivalent circuit of the overhead line over lossy soil is computed by method of moments (MoM) and then for the problem under consideration, a nonlinear equivalent circuit in the frequency domain is proposed. Finally applying inte...
متن کاملTransient Analysis of the Single-Conductor Overhead Lines Connected to Grid-Grounded Arrester under Direct Lightning by Means of GA
In this paper, genetic algorithm-based approach for transient analysis of single transmission line connected to arrester is proposed. In this approach, the lightning channel striking the overhead line is first represented by a current source and this source is truncated by a finite set of frequency harmonies in time domain. Norton equivalent circuit viewed across arrester is then computed by me...
متن کاملبررسی جامع اضافهولتاژهای صاعقه در مزارع بادی با پیکربندیهای متفاوت به همراه تاثیر سیستم زمین
This paper is treated with major risks applied by lightning strikes to wind farms. The risks illustrated in this research include overvoltage caused by direct and indirect effects of lightning strikes on any components of wind farm. As demands for electrical energy throughout our world is increased more and more nowadays, wind power plants are extended in every possible locations correspondingl...
متن کاملINVERSE FREQUENCY RESPONSE ANALYSIS FOR PIPELINES LEAK DETECTION USING THE PARTICLE SWARM OPTIMIZATION
Inverse Transient Analysis (ITA) is a powerful approach for leak detection of pipelines. When the pipe transient flow is analyzed in frequency domain the ITA is called Inverse Frequency Response Analysis (IFRA). To implement an IFRA for leak detection, a transient state is initiated in the pipe by fast closure of the downstream end valve. Then, the pressure time history at the valve location is...
متن کاملارائۀ یک روش نوین بهمنظور مدلسازی جامع سیستم زمین دکلهای فشار قوی و برج توربینهای بادی با استفاده از روش برازش برداری
In the past, grounding systems usually were modeled by an individual Resistor. This estimation is useful only at low frequencies, while in high frequencies, the inductance of the grounding system plays the main role to identify the phase and amplitude of that. In recent years, as wind farms grow rapidly throughout the world, the grounding system and ground impedance of wind turbine towers under...
متن کامل