Depth-of-Field of the Accommodating Eye

نویسندگان

  • Paula Bernal-Molina
  • Robert Montés-Micó
  • Richard Legras
  • Norberto López-Gil
چکیده

PURPOSE To obtain experimental values of the depth-of-field (DOFi) of the human eye for different accommodative states. METHODS First, the monochromatic ocular wavefront of seven eyes from young subjects (mean [±SD] age, 29.7 [±7.7] years) was measured at eight different accommodative demands (ADs) (from -1 to 6 diopters [D] in steps of 1 D). Then, in a second part, accommodation was paralyzed and an adaptive optics system was used to correct the aberrations of the paralyzed eye and to simulate, with the aid of an artificial pupil, the wavefront of the accommodated eye. The simulation was performed for each AD measured in the first part of the experiment. A Badal system was used to modify the stimulus vergence so as to obtain three repeated measurements of the subjective DOFi, based on the criterion of an objectionable blur. RESULTS When increasing AD from 0 to 6 D, the mean intersubject pupil diameter and DOFi changed from 5.70 to 4.62 mm and from 0.85 ± 0.26 D to 1.07 ± 0.19 D, respectively. All subjects presented a similar DOFi for all AD (intrasubject SD never exceeded 0.23 D). Paraxial accommodation response showed a lag that increased with the AD. For the lowest (0 D) and the highest (6 D) values of AD, the refractive state of the eye was close to the nearest and furthermost ends of the DOFi, respectively. CONCLUSIONS The visual system takes advantage of the DOFi to change the refractive state less than necessary to form the paraxial image at the retina when it comes to focusing a near target (5 to 6 D of AD). This indicates that the main purpose of accommodation is not to maximize retinal image quality but to form one that is good enough.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی ارتباط کنترل عمق بیهوشی و میزان شفافیت فیلد عمل در اعمال جراحی با فیلد محدود (گوش، بینی و سینوس‌ها) در بیمارستان مرادی رفسنجان در سال 1394: یک گزارش کوتاه

Background and Objective: Operation field in surgeries like sinus endoscopy, rhinoplasty, tympanoplasty, and mastoidectomy is limited and difficult to achieve. Bleeding in the field of these surgeries can opaque operation fields and ultimately affect surgery outcome. This study aimed to evaluate the relationship between anesthesia depth and transparency of operation field in the first and secon...

متن کامل

بررسی اثر تغییر انرژی بر توزیع عمق-دوز در پروتون درمانی تومور چشمی با استفاده از کد MCNPX

Introduction: Depth-dose distribution curve of protons in the matter has a maximum is called Bragg peak. Bragg peak of a monoenergetic proton beam is too narrow. The spread out Bragg peak should be created for full coverage of the tumor. The spread out Bragg peak is obtained in the depth of the tumor with superposition of the several Bragg peaks. The aim of this study was coverage of an eye tum...

متن کامل

Recognition and Treatment of Eye Diseases in Andalusia

Muslim ophthalmologists have made significant achievements in the field of ophthalmology in all Islamic lands and territories, especially in Andalusia. Andalusian scientists have written several works related to medicine and ophthalmology that introduce us to their activities in this field. The main purpose of this study is to review the activities performed in Andalusia regarding ophthalmology...

متن کامل

Dosimetry Comparison of Water Phantom and Complete Eye Definition for 125I and 103Pd Brachytherapy Plaques

Introduction: In this paper, by complete definition of human eye containing the various parts and their materials, the difference between this model and a homogeneous water phantom are compared for two ophthalmic plaques using 125I and 103Pd. Material and methods: The simulation of the two phantoms were performed in the MCNP-4C code and by using the geometry of a three-dimensional eye, differen...

متن کامل

Ultrasonographic findings of some ocular structures in Caspian miniature horse

Ultrasonography is a relatively easy, safe and non-invasive examination method which can be used in diagnosis of ocular disorders as complementary to routine ophthalmic examinations. As there has been no collated study undertaken on the normal measurements of ocular structures in Caspian miniature horse, obtaining these measurements could be a benchmark to diagnose some of the diseases and eye ...

متن کامل

Numerical Analysis of the Thermal Interaction of Cell Phone Radiation with Human Eye Tissues

Introduction: The present study aimed to present a numerical analysis of the penetration depth,  specific absorption rate (SAR), and temperature rise in various eye tissues with varying distance between radiation source and exposed human eye tissues (i.e., cornea, posterior chamber, anterior chamber, lens, sclera, vitreous humor, and iris) at frequencies of 900 and1800 MHz. Materials and Method...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 91  شماره 

صفحات  -

تاریخ انتشار 2014