In vivo aqueous humor oxygen tension--as estimated from measurements on bare stroma.

نویسندگان

  • R N Kleinstein
  • M Kwan
  • I Fatt
  • B A Weissman
چکیده

Aqueous humor oxygen tension of the in vivo rabbit eye was estimated by a relatively atraumatic procedure. The anterior corneal surface of the eye was first scraped free of its epithelial layer. A polarographic oxygen electrode was then used to measure the oxygen tension at the bare stromal surface. Aqueous humor oxygen tension can be estimated from this measured steady-state stromal surface oxygen tension by correcting the measured oxygen tension for the tension drop across the stroma and endothelium. When animals breathed room air (155 mm Hg oxygen tension), the oxygen tension of the aqueous humor was 13 mm Hg; this rose to 150 mm Hg when the inspired oxygen tension was 713 mm Hg.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In vivo measurements of oxygen tension in the cornea, aqueous humor, and anterior lens of the open eye.

Measurements of oxygen profiles across the cornea, aqueous humor, and anterior lens differed from previously calculated values. The aqueous humor oxygen tension in paiticular also differed from previously measured values, being approximately 20 mm. Hg higher. Reasons for these differences are discussed. The tissue oxygen gradients measured confirm the high Qos of lenticular and corneal epitheli...

متن کامل

The Effects of Glaucoma Drainage Devices on Oxygen Tension, Glycolytic Metabolites, and Metabolomics Profile of Aqueous Humor in the Rabbit

Purpose Glaucoma drainage device (GDD) implantation can lead to corneal decompensation. We evaluated changes over time in oxygen tension and in the metabolic environment of the aqueous humor after GDD implantation in the rabbit eye. Methods Ahmed Glaucoma Valves were implanted in the left eyes of eight male New Zealand white rabbits. Right eyes were used as a control. Oxygen tension was measu...

متن کامل

Oxygen Tension in the Aqueous Humor of Human Eyes under Different Oxygenation Conditions

PURPOSE To measure oxygen tension in the aqueous humor of human eyes under different oxygenation conditions. METHODS This prospective comparative interventional case series consisted of two parts. In the first part, 120 consecutive patients scheduled for cataract surgery were randomized into group I (control group) in which surgery was performed under local anesthesia inhaling 21% oxygen; gro...

متن کامل

The aqueous humor is capable of generating and degrading H2O2.

PURPOSE To determine the ability of the aqueous humor to generate and degrade H2O2, the effect of environmental factors such as oxygen tension and temperature, and the constituents contributing to the observed results. METHODS Aqueous humor was carefully removed from bovine eyes within 3 hours of death. Standard and new techniques were used to follow H2O2 degradation and formation. Catalase a...

متن کامل

Oxygen tension in the anterior chamber of the rabbit eye.

The oxygen tension in the aqueous humor in the anterior chamber of rabbit eyes was measured continuously with a polarographic electrode. The normal oxygen tension in the anterior chamber was 23 +/- 2 mm Hg (mean +/- SD, n = 4). A contact lens was then placed on the cornea for at least 10 min and the drop in oxygen tension recorded. A hard polymethylmethacrylate lens reduced the oxygen tension b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 21 3  شماره 

صفحات  -

تاریخ انتشار 1981