Reference values of interrupter respiratory resistance in healthy preschool white children.

نویسندگان

  • E Lombardi
  • P D Sly
  • G Concutelli
  • E Novembre
  • G Veneruso
  • G Frongia
  • R Bernardini
  • A Vierucci
چکیده

BACKGROUND Interrupter respiratory resistance (Rint) is reported to be useful in evaluating lung function in poorly collaborating patients. However, no reference values are available from large samples of preschool children using the standard interrupter method. The aim of this study was to define reference Rint values in a population of healthy preschool children. METHODS Rint was assessed without supporting the cheeks in children with no history of wheeze from six kindergartens. To evaluate the effects of upper airway compliance on Rint in healthy children, an additional group of preschool children with either no history of wheeze or no respiratory symptoms at the time of testing underwent Rint measurements in our lung function laboratory with and without supporting the cheeks. Short term (about 1 minute apart) and long term (mean 2.5 months apart) repeatability of Rint measurements (2 SDs of the mean paired difference between measurements) was also assessed in children referred for cough or wheeze. RESULTS A total of 284 healthy white children (age range 3.0-6.4 years) were evaluated. Mean inspiratory and expiratory Rint (RintI and RintE) did not differ significantly in boys and girls. Age, height, and weight showed a significant inverse correlation with both RintI and RintE in the univariate analysis with linear regression. Multiple regression with age, height, and weight as the independent variables showed that all three variables were significantly and independently correlated with RintI, whereas only height was significantly and independently correlated with RintE. Supporting the cheeks had no significant effect on RintI (n=29, median 0.673 v 0.660 kPa/l.s, p=0.098) or RintE (n=39, median 0.702 v 0.713 kPa/l.s, p=0.126). Short term repeatability was 0.202 kPa/l.s for RintI (n=50) and 0.242 kPa/l.s for RintE (n=69). Long term repeatability was 0.208 kPa/l.s for RintE (n=26). CONCLUSIONS We have reported reference Rint values in preschool white children and have demonstrated the usefulness of this technique in assessing lung function in this age group.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurements of interrupter resistance: reference values for children 3-13 yrs of age.

The interrupter technique is a convenient and sensitive technique for studying airway function in subjects who cannot actively participate in (forced) ventilatory function tests. Reference values for preschool children exist but are lacking for children >7 yrs. Reference values were obtained for expiratory interrupter resistance (R(int,e)) in 208 healthy Dutch Caucasian children 3-13 yrs of age...

متن کامل

Airway resistance measured by the interrupter technique: normative data for 2-10 year olds of three ethnicities.

BACKGROUND AND AIMS The measurement of airway resistance using the interrupter technique (R(int)) is feasible in preschool children and other subjects unable to undertake spirometry. This makes it potentially useful for the measurement of lung function in these groups. Commercial devices use different algorithms to measure pressure and flow from which R(int) is derived. This study provides norm...

متن کامل

A portable device based on the interrupter technique for measuring airway resistance in preschool children.

The interrupter technique for measuring airway resistance is a noninvasive method reported to require minimal subject cooperation. Therefore it has a good potential for use in young children who are not able to cooperate with conventional lung function tests. The interrupter method is based on transient interruption of airflow at the mouth for a brief period during which alveolar pressure equil...

متن کامل

Normative Data and Predictive Equation of Interrupter Airway Resistance in Preschool Children in Japan.

Measurement of interrupter airway resistance (Rint) is a convenient alternative to standard spirometry for assessing respiratory function in uncooperative young children. The aim of the present prospective study was to establish the normative data and predictive equation of Rint in Japanese preschool children. A total of 214 children were enrolled from a single kindergarten; however, 129 were e...

متن کامل

Reference ranges for interrupter resistance technique: the Asthma UK Initiative.

Measuring interrupter resistance (R(int)) is an increasingly popular lung function technique and especially suitable for preschool children because it is simple, quick and requires only passive cooperation. A European Respiratory Society (ERS)/American Thoracic Society (ATS) Task Force recently published empirical recommendations related to procedures, limitations and interpretation of the tech...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Thorax

دوره 56 9  شماره 

صفحات  -

تاریخ انتشار 2001