Pulse dye densitometry and indocyanine green plasma disappearance in ASA physical status I-II patients.

نویسندگان

  • Marije Reekers
  • Mischa J G Simon
  • Fred Boer
  • René A G Mooren
  • Jack W van Kleef
  • Albert Dahan
  • Jaap Vuyk
چکیده

BACKGROUND Indocyanine green plasma disappearance rate (ICG-PDR) is used to evaluate hepatic function. Although hepatic failure is generally said to occur with an ICG-PDR <18%/min, ICG disappearance rate is poorly defined in the healthy population, and a clear cutoff value of ICG-PDR that discriminates between normal hepatic function and hepatic failure has not yet been described. We therefore defined the ICG disappearance rate in an otherwise healthy patient population. In addition, we evaluated the noninvasive measurement of ICG-PDR (transcutaneously by pulse dye densitometry [PDD] at the finger and the nose) and compared these with the simultaneously performed invasive measurements of ICG-PDR (in arterial blood). METHODS In patients without signs of liver disease, scheduled for elective nonhepatic surgery, 10 mg ICG was administered IV and ICG-PDR measured by PDD (DDG-2001, Nihon Kohden, Tokyo, Japan). In a subset of patients, arterial blood samples were gathered to compare PDD with invasive ICG measurements. Methods were compared using Bland-Altman analysis. The results of our study and reported studies on discriminative use of ICG-PDR in assessing liver failure were used to construct receiver operating characteristic curves. RESULTS Forty-one patients were studied: 33 using the finger probe and 8 using the nose probe. The mean +/- SD noninvasive ICG-PDR in this patient population is 23.1% +/- 7.9%/min (n = 41) with a range of 9.7% to 43.2%/min. Bias (+/-2 sd, limits of agreement) for ICG-PDR measured by PDD compared with those measured in arterial blood were 1.6%/min (-5.2% to 8.3%/min) for the finger probe and -6.0%/min (-15.5% to 3.4%/min) for the nose probe. CONCLUSION ICG-PDR values in a population without liver failure ranged well below 18%/min, cited as the cutoff value for hepatic failure. This cutoff value needs reconsideration. In addition, we conclude that the ICG concentration is adequately determined noninvasively by PDD.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The stimulant effect of drugs on indocyanine green clearance by the liver.

The rate of removal of a standard dose of 25 mg indocyanine green was studied in 67 patients at the bedside using dichromatic ear densitometry. The determination of the percentage disappearance rate per minute and the half life of the dye permitted separation of patients into three groups: those with normal liver function, those with liver damage, and a group taking opiates (9), anticonvulsants...

متن کامل

Pulse dye densitometry: a novel bedside monitor of circulating blood volume.

INTRODUCTION Monitoring of circulating blood volume is important in the management of critically ill patients. Current methods of circulating blood volume measurements such as indicator dilution using radioisotopes or Evans blue dye are unsuitable for clinical application as these tests do not allow for frequent repeated measurements to be done. A direct bedside measurement of circulating blood...

متن کامل

The new clearance method for hepatic diagnostics.

New multiparametric analysis and method of their evaluation were derived. The bolus dye injection is used for evaluation of ICG (indicyaningreen) and BSP (bromsulphophtalein) kinetics. This arrangement is a form of spectrophotometric measurement of BSP in plasma and/or pulse dye densitometry of ICG. Clearance values enable to differentiate liver diseases and to add their clinical staging. Patho...

متن کامل

Sensitivity and specificity of plasma disappearance rate of indocyanine green as a prognostic indicator in acute liver failure

BACKGROUND In patients presenting with acute liver failure (ALF) prediction of prognosis is vital to determine the need of transplantation. Based on the evidence that plasma disappearance rate of indocyanine green (ICG-PDR) correlates with liver cell function, we evaluated the ability of ICG-PDR measured by pulse dye densitometry to predict outcome in patients with acute liver failure. METHOD...

متن کامل

Cerebral distribution of cardiac output in newborn infants.

Cerebral blood flow and output of the left ventricle were simultaneously investigated in 17 infants using multichannel near infrared spectroscopy and pulse dye densitometry with indocyanine green. Cardiac output and cerebral blood flow were positively related. The control of cardiac output is important in the regulation of cerebral blood flow in infants.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesia and analgesia

دوره 110 2  شماره 

صفحات  -

تاریخ انتشار 2010