A New Method to Derive Fetal Heart Rate from Maternal Abdominal Electrocardiogram: Monitoring Fetal Heart Rate during Cesarean Section

نویسندگان

  • Huei-Ming Yeh
  • Yi-Chung Chang
  • Chen Lin
  • Chien-Hung Yeh
  • Chien-Nan Lee
  • Ming-Kwang Shyu
  • Ming-Hui Hung
  • Po-Ni Hsiao
  • Yung-Hung Wang
  • Yu-Hsin Tseng
  • Jenho Tsao
  • Ling-Ping Lai
  • Lian-Yu Lin
  • Men-Tzung Lo
چکیده

BACKGROUND Monitoring of fetal heart rate (FHR) is important during labor since it is a sensitive marker to obtain significant information about fetal condition. To take immediate response during cesarean section (CS), we noninvasively derive FHR from maternal abdominal ECG. METHODS We recruited 17 pregnant women delivered by elective cesarean section, with abdominal ECG obtained before and during the entire CS. First, a QRS-template is created by averaging all the maternal ECG heart beats. Then, Hilbert transform was applied to QRS-template to generate the other basis which is orthogonal to the QRS-template. Second, maternal QRS, P and T waves were adaptively subtracted from the composited ECG. Third, Gabor transformation was applied to obtain time-frequency spectrogram of FHR. Heart rate variability (HRV) parameters including standard deviation of normal-to-normal intervals (SDNN), 0V, 1V, 2V derived from symbolic dynamics of HRV and SD1, SD2 derived from Poincareé plot. Three emphasized stages includes: (1) before anesthesia, (2) 5 minutes after anesthesia and (3) 5 minutes before CS delivery. RESULTS FHRs were successfully derived from all maternal abdominal ECGs. FHR increased 5 minutes after anesthesia and 5 minutes before delivery. As for HRV parameters, SDNN increased both 5 minutes after anesthesia and 5 minutes before delivery (21.30±9.05 vs. 13.01±6.89, P < 0.001 and 22.88±12.01 vs. 13.01±6.89, P < 0.05). SD1 did not change during anesthesia, while SD2 increased significantly 5 minutes after anesthesia (27.92±12.28 vs. 16.18±10.01, P < 0.001) and both SD2 and 0V percentage increased significantly 5 minutes before delivery (30.54±15.88 vs. 16.18±10.01, P < 0.05; 0.39±0.14 vs. 0.30±0.13, P < 0.05). CONCLUSIONS We developed a novel method to automatically derive FHR from maternal abdominal ECGs and proved that it is feasible during CS.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A PCA/ICA based Fetal ECG Extraction from Mother Abdominal Recordings by Means of a Novel Data-driven Approach to Fetal ECG Quality Assessment

Background: Fetal electrocardiography is a developing field that provides valuable information on the fetal health during pregnancy. By early diagnosis and treatment of fetal heart problems, more survival chance is given to the infant.Objective: Here, we extract fetal ECG from maternal abdominal recordings and detect R-peaks in order to recognize fetal heart rate. On the next step, we find a be...

متن کامل

P-184: Investigation of Electronic Fetal Monitoring Application during Labor with Cesarean Section and Apgar Score

Background: Electronic fetal monitoring was used in many hospitals before labor and during delivery . The objective of this study was to investigate whether the use of fetal monitoring had effect on neonatal outcomes and cesarean section rate. Materials and Methods: A prospective study on monitoring neonatal Apgar and kind of delivery data, from deliveries occurring at Shahid Sadughi hospital i...

متن کامل

Intrapartum heart rate ambiguity: a comparison of cardiotocogram and abdominal fetal electrocardiogram with maternal electrocardiogram.

OBJECTIVE/AIMS To investigate the presence of signal ambiguity of intrapartum fetal heart rate (FHR) monitoring during delivery by comparing simultaneous cardiotocogram (CTG), abdominal fetal electrocardiogram (ECG) with continuous maternal ECG. METHODS A total of 144 simultaneous CTG (Corometrics 250 series), abdominal fetal ECG (Monica -AN24™) and maternal ECG (Monica AN24™) recordings were...

متن کامل

Fetal heart rate monitoring: from Doppler to computerized analysis.

The monitoring of fetal heart rate (FHR) status is an important method to check well-being of the baby during labor. Since the electronic FHR monitoring was introduced 40 years ago, it has been expected to be an innovative screening test to detect fetuses who are becoming hypoxic and who may benefit from cesarean delivery or operative vaginal delivery. However, several randomized controlled tri...

متن کامل

Comment on the article "accuracy and reliability of fetal heart rate monitoring using maternal abdominal surface electrodes".

OBJECTIVE Compare the accuracy and reliability of fetal heart rate identification from maternal abdominal fetal electrocardiogram signals (ECG) and Doppler ultrasound with a fetal scalp electrode. DESIGN Prospective open method equivalence study. SETTING Three urban teaching hospitals in the Northeast United States. SAMPLE 75 women with normal pregnancies in labor at >37 weeks of gestatio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015