The first experiences with the lotus valve system in Turkey as an alternative valve system in TAVI

نویسندگان

  • Serkan Aslan
  • Derya Öztürk
  • Mehmet Gül
  • Aydın Yıldırım
  • Nevzat Uslu
چکیده

Transcatheter aortic valve implantation (TAVI) is an alternative therapy to surgical aortic valve replacement (AVR) in inoperable patients with severe aortic stenosis (AS). Currently, new valve systems are being developed, and we experienced TAVI with the Boston Scientific Lotus Valve System (Marlborough, Massachusetts, USA) with two patients for the first cases in Asia-Pacific countries and Turkey. The first patient was a 77-yearold woman with severe AS with an echocardiographic aortic valve area of 0.8 cm2 and a mean aortic pressure gradient of 52 mm Hg, and her left ventricular function (LVEF) was 35%. Her logistic EuroSCORE was 38%, and she had New York Heart Association (NYHA) functional class III dyspnea. The other patient was a 82-year-old woman with severe AS; in her echocardiographic examination, the aortic valve area was 0.6 cm2, and the mean aortic pressure gradient was 62 mm Hg, with an LVEF of 52%. Her logistic EuroSCORE was 29%, and she had NYHA class III dyspnea. The Lotus valve system has some advantages, such as it does not require rapid pacing during valve system implantation and balloon pre-dilatation, and it has a specific pre-shaped guidewire that has two types varying the length and curve, designed according to the size of the left ventricular cavity diameter. This valve system supports an ability to change positions while opening the valve system at the aortic valve level. Likely, if the chosen aortic valve size and aortic roof size do not match, the valve system could be taken back through the sheath. The other important feature of the Lotus valve is success in the prevention of paravalvular leak (PVL), which is related with increased mortality rate (1). In the REPRİSE I trial, in which the safety and efficacy of the Lotus valve were studied, one patient had stroke, PVL was seen in 3 of 11 patients, and permanent pacemaker implantation was required due to complete heart block, left bundle branch block, or atrial fibrillation with slow ventricular rate in 4 of 11 patients, while the requirement of permanent pacemaker implantation varies between 3% and 40% with other valve systems (1, 2). In our patients, the follow-up echocardiography showed a wellfunctioning prosthesis, with a mean gradient of 7 mm Hg and 9 mm Hg, respectively. There was no paravalvular leak or pacemaker implantation required in either patient. The patients were clinically stable at 30 days of follow-up after the procedure. In summary, the ability to change valve position to obtain optimal implantation placement and the decrease in PVL rate are the most important reasons for using the Lotus valve system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Trans-catheter Bioprosthetic Heart Valve Implantation in Iran (Tehran Heart Centre Experience)

Introduction: With the development of interventional cardiology in the world, in addition to coronary and aortic diseases, the treatment of heart valve diseases through catheters has recently begun. The treatment of aortic stenosis (which was only possible with open surgery and valve replacement) was first performed in the world in 2002 by Alain Cribier in France with catheter insertion of the ...

متن کامل

Design Servo System Type and Positioning of Pole Observer Full Rank a Piezoelectric Servo Valve without Integrator

In this paper, the method of modern control approach for the design of controller and observer is used. Other functions such as neural controllers - or fuzzy sliding mode control can be found in this work and the results are compared. First, a dynamic model of the servo valve is intended for the governing equations in state-space form expression are obtained. Due to the system integrator is exp...

متن کامل

Severe Persistant Cyanosis in a Newborn Due to Prominent Eustachian Valve

ABSTRACTThe valves of right horn of systemic venous sinus are prominent structures within the right atrium during early embryonic period. Involution of these structures may not be complete, resulting in a spectrum of anatomical presentations such as cyanosis. A full-term male neonate referred to our hospital for precise evaluation of severe cyanosis on the first day of life. Echocardiographic e...

متن کامل

A New Approach to Flow Network Analysis of an Engine Lubrication System

In order to develop more efficient engines, it is essential to optimize the lubrication circuit of the power train systems. In this paper, during an engine design and development process, a network analysis of the engine lubrication system is described in detail. Two elements have been added to the lubrication circuit in the modified engine. These elements are hydraulic lifters and an Anti-d...

متن کامل

Successful Use of Two Thrombolytic Drugs in Prosthetic Mitral and Aortic Valve Thrombosis

Introduction: Prosthetic valve thrombosis is a rare and severe complication of valve replacement, most often encountered with a mechanical prosthesis. The significant morbidity and mortality associated with this condition warrant rapid diagnostic evaluation. Although surgery is the first-line therapy in symptomatic obstructive mechanical valve thrombosis, thrombolytic therapy has been used as a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2015