Reliability of measurements of concentric and eccentric isokinetic loading.

نویسندگان

  • T J Tredinnick
  • P W Duncan
چکیده

The purpose of this study was to assess the reliability of a method for testing peak torque and work output of the knee extensor muscle during concentric and eccentric loading at three velocities of exercise (60 degrees, 120 degrees, and 180 degrees/sec). Fourteen healthy men (23-32 years of age) performed exercises of the quadriceps femoris muscles during concentric and eccentric loading, with a five-second pause between each contraction. Three different tests were performed on different occasions. The first exercise session was a practice session, and the next two sessions were established to collect data in a test-retest format. Peak torque and work were measured for the two testing sessions. The results of this study demonstrated that with a very specific protocol, the reliability of concentric peak torque and work measurements was excellent at 60 degrees and 120 degrees/sec and good at 180 degrees/sec. In contrast, reliability of eccentric peak torque and work measurements was good at 120 degrees and 180 degrees/sec but low at 60 degrees/sec.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

TrKB and FNDC5 Gene Expression and SG6K1 Protein Response to Eccentric and Concentric Resistance Activity in Young Men

Background: The aim of the present study was to investigate the expression of TrKB, FNDC5 and SG6K1 protein in response to eccentric and concentric resistance training in healthy subjects. Methods: 10 healthy men were randomly assigned to two groups of concentric and eccentric contractions of 5 individuals each. Isokinetic contraction protocols included eccentric and concentric knee extension ...

متن کامل

The Comparison of Isokinetic Parameters of Hip and Knee Joint Muscles in Professional Soccer Players with Athletic Groin Pain and Healthy One: Implications for Sports Injuries Prevention

Aims and background: This study aimed to investigate the comparison of isokinetic parameters of hip and knee joint muscles in professional soccer players with athletic groin pain (AGP) and healthy ones. Material and Methods: 32 soccer players (control group (n=16) and AGP group (n=16)) who take part in the first and second division league participated in this study. The isokinetic dynamometer ...

متن کامل

Effects of a Single Session of Eccentric or Concentric Resistance Exercise on Relative Expression of BDNF, PAX7 and IGF-1 in Young Men

Background and Objectives: The aim of the present study was to investigate effectsof a single sessionof eccentric or concentric resistance exercise on relative expression of BDNF, PAX7 and IGF-1 in healthy participants. Materials and Methods: In a field trial, ten healthy young men were randomly assigned into two equal groupsof concentric and eccentric contractions. Isokinetic contraction prot...

متن کامل

Reliability of Concentric, Eccentric and Isometric Knee Extension and Flexion when using the REV9000 Isokinetic Dynamometer

The aim of this study was to assess the reliability of isokinetic and ISO knee extensor and flexor muscle strength when using the REV9000 (Technogym) isokinetic dynamometer. Moreover, the reliability of several strength imbalance indices and bilateral ratios were also examined. Twenty-four physically active healthy subjects (age 23±3 years) underwent three testing sessions, two on the same day ...

متن کامل

Reliability of Assessing Indices of Isokinetic Leg Strength in Pubertal Soccer Players

Using 95% limits of agreement (LOA), this study examined the reproducibility of indices of isokinetic leg strength in pubertal soccer players. Following familiarization, 23 boys performed isokinetic assessments of the knee joint muscles at 1.08, 2.16, and 4.32 rad/s during concentric exercise and at 2.16 rad/s during eccentric actions on two separate occasions. Peak torque values were recorded ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physical therapy

دوره 68 5  شماره 

صفحات  -

تاریخ انتشار 1988