Human eyes do not need monochromatic aberrations for dynamic accommodation

نویسندگان

  • Paula Bernal-Molina
  • Iván Marín-Franch
  • Antonio J Del Águila-Carrasco
  • Jose J Esteve-Taboada
  • Norberto López-Gil
  • Philip B Kruger
  • Robert Montés-Micó
چکیده

PURPOSE To determine if human accommodation uses the eye's own monochromatic aberrations to track dynamic accommodative stimuli. METHODS Wavefront aberrations were measured while subjects monocularly viewed a monochromatic Maltese cross moving sinusoidally around 2D of accommodative demand with 1D amplitude at 0.2 Hz. The amplitude and phase (delay) of the accommodation response were compared to the actual vergence of the stimulus to obtain gain and temporal phase, calculated from wavefront aberrations recorded over time during experimental trials. The tested conditions were as follows: Correction of all the subject's aberrations except defocus (C); Correction of all the subject's aberrations except defocus and habitual second-order astigmatism (AS); Correction of all the subject's aberrations except defocus and odd higher-order aberrations (HOAs); Correction of all the subject's aberrations except defocus and even HOAs (E); Natural aberrations of the subject's eye, i.e., the adaptive-optics system only corrected the optical system's aberrations (N); Correction of all the subject's aberrations except defocus and fourth-order spherical aberration (SA). The correction was performed at 20 Hz and each condition was repeated six times in randomised order. RESULTS Average gain (±2 standard errors of the mean) varied little across conditions; between 0.55 ± 0.06 (SA), and 0.62 ± 0.06 (AS). Average phase (±2 standard errors of the mean) also varied little; between 0.41 ± 0.02 s (E), and 0.47 ± 0.02 s (O). After Bonferroni correction, no statistically significant differences in gain or phase were found in the presence of specific monochromatic aberrations or in their absence. CONCLUSIONS These results show that the eye's monochromatic aberrations are not necessary for accommodation to track dynamic accommodative stimuli.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Monochromatic aberrations in the accommodated human eye

The wave-front aberration of the human eye was measured for eight subjects using a spatially resolved refractometer (a psychophysical ray-tracing test). The eyes were undilated and presented with accommodative stimuli varying from 0 to -6 diopters. Monochromatic wave-front aberrations tend to increase with increasing levels of accommodation, although there are substantial individual variations ...

متن کامل

Measurement of monochromatic ocular aberrations of human eyes as a function of accommodation by the howland aberroscope technique

Further development of the objective version of the Howland and Howland [(1976) Science, 193, 580-582; (1977) Journal of the Optical Society of America, 67, 1508-1518] aberroscope technique for measuring ocular aberrations is described. Compensation for refractive corrections and calibration is discussed. The technique was used to investigate the effect of accommodation upon the monochromatic a...

متن کامل

Monochromatic aberrations and myopia

The monochromatic aberrations present in the eyes of a group of 21 young myopic subjects and 16 young emmetropic subjects were measured along the visual axis at three levels of accommodation. The aberrations were measured using a modified aberroscope technique which makes use of a retinal camera to photograph the shadow image of the aberroscope grid on the retina, while accommodation levels of ...

متن کامل

Effect of temporal location of correction of monochromatic aberrations on the dynamic accommodation response

Dynamic correction of monochromatic aberrations of the eye is known to affect the accommodation response to a step change in stimulus vergence. We used an adaptive optics system to determine how the temporal location of the correction affects the response. The system consists of a Shack-Hartmann sensor sampling at 20 Hz and a 37-actuator piezoelectric deformable mirror. An extra sensing channel...

متن کامل

Recent advances in measurement of monochromatic aberrations of human eyes.

The field of aberrations of the human eye is moving rapidly, being driven by the desire to monitor and optimise vision following refractive surgery. It is important for ophthalmologists and optometrists to have an understanding of the magnitude of various aberrations and how these are likely to be affected by refractive surgery and other corrections. In this paper, I consider methods used to me...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 37  شماره 

صفحات  -

تاریخ انتشار 2017