Simple assessment of cerebral hemodynamics using single-slab 3D time-of-flight MR angiography in patients with cervical internal carotid artery steno-occlusive diseases: comparison with quantitative perfusion single-photon emission CT.
نویسندگان
چکیده
BACKGROUND AND PURPOSE Visualization of the peripheral arteries on single-slab 3D time-of-flight (TOF) MR angiography (MRA) can reflect blood flow velocity. The velocity in the middle cerebral artery (MCA) may correlate with cerebrovascular reactivity (CVR) to acetazolamide, which can be used to assess hemodynamic impairment. The goal of this study was to compare the signal intensity of the MCA on MRA versus CVR quantified by perfusion single-photon emission CT (SPECT). MATERIALS AND METHODS The signal intensity of the MCA on single-slab 3D time-of-flight MRA was graded according to the ability to visualize the MCA in 108 cerebral hemispheres of 87 patients with unilateral or bilateral cervical internal carotid artery (ICA) steno-occlusive diseases. SPECT-CVR was also calculated by measuring cerebral blood flow before and after acetazolamide challenge. Ten healthy subjects were studied to obtain control SPECT-CVR values. All subjects provided written informed consent before the study. RESULTS CVR was significantly lower in cerebral hemispheres with reduced MCA signal intensity than in those with normal intensity (P < .05). When the reduced signal intensity of the MCA on MRA was defined as abnormal, and when a CVR less than the mean--2 SD of healthy subjects was defined as reduced, MRA grading resulted in a 86.2% sensitivity and 69.6% specificity, with 51.0% positive-predictive and 93.2% negative-predictive values to detect reduced CVR. CONCLUSIONS This simple MRA method can assess hemodynamic impairment with a high negative-predictive value.
منابع مشابه
Prediction of cerebral hyperperfusion after carotid endarterectomy using cerebral blood volume measured by perfusion-weighted MR imaging compared with single-photon emission CT.
BACKGROUND AND PURPOSE Cerebral hyperperfusion syndrome is a rare but serious complication of carotid revascularization, including carotid endarterectomy (CEA) and carotid stent placement, which can occur in patients with preoperative impairments in cerebral hemodynamics. The purpose of this study was to determine whether preoperative cerebral blood volume (CBV) measured by perfusion-weighted M...
متن کاملRole of Multimodal Evaluation of Cerebral Hemodynamics in Selecting Patients with Symptomatic Carotid or Middle Cerebral Artery Steno-occlusive Disease for Revascularization.
BACKGROUND The circle of Willis provides collateral pathways to perfuse the affected vascular territories in patients with severe stenoocclusive disease of major arteries. The collateral perfusion may become insufficient in certain physiological circumstances due to failed vasodilatory reserve and intracranial steal phenomenon, so-called 'Reversed-Robinhood syndrome'. We evaluated cerebral hemo...
متن کاملTracer delay-insensitive algorithm can improve reliability of CT perfusion imaging for cerebrovascular steno-occlusive disease: comparison with quantitative single-photon emission CT.
BACKGROUND AND PURPOSE Reliability of CT perfusion (CTP) algorithms has not been fully validated. We investigated whether the cerebral blood flow (CBF) values obtained by using a dynamic CTP technique with a tracer delay-insensitive deconvolution algorithm are more accurate than those obtained by using CTP with delay-sensitive algorithms in unilateral cerebrovascular steno-occlusive disease, wh...
متن کاملEfficacy of superficial temporal artery-middle cerebral artery bypass in cerebrovascular steno-occlusive diseases: Hemodynamics assessed by perfusion computed tomography
OBJECTIVES Our purpose of this study was to assess the cerebral hemodynamic improvement with perfusion computed tomography (CT), before and after superficial temporal artery (STA) to middle cerebral artery (MCA) bypass surgery in patients with cerebrovascular steno-occlusive diseases including both moyamoya disease and nonmoyamoya steno-occlusions. MATERIALS AND METHODS Twenty-four STA-MCA by...
متن کاملCorrelative assessment of hemodynamic parameters obtained with T2*-weighted perfusion MR imaging and SPECT in symptomatic carotid artery occlusion.
BACKGROUND AND PURPOSE Perfusion MR imaging and single-photon emission CT (SPECT) are commonly used to evaluate hemodynamic status in patients with symptomatic occlusive cerebrovascular disease. These techniques rely on different underlying physiological mechanisms, and the data may not correspond. We studied the relationship between hemodynamic parameters obtained with these two methods. MET...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 30 3 شماره
صفحات -
تاریخ انتشار 2009