Late-onset Candida keratitis after Descemet stripping automated endothelial keratoplasty: clinical and confocal microscopic report.

نویسندگان

  • Amanda Ortiz-Gomariz
  • Alejandro Higueras-Esteban
  • Ángel Ramón Gutiérrez-Ortega
  • José M González-Méijome
  • Angeles Arance-Gil
  • César Villa-Collar
چکیده

PURPOSE To report clinical and confocal microscopy features of late-onset Candida albicans keratitis after Descemet stripping automated keratoplasty (DSAEK). METHODS We performed clinical and confocal scan on a patient who underwent DSAEK and phacoemulsification for Fuchs endothelial dystrophy and cataract. RESULTS A 76-year-old woman who underwent uneventful DSAEK and phacoemulsification presented with white to cream deposits 3 months after DSAEK. Confocal microscopy showed a hyperintense deposit at the lenticule and interface. Confocal scan also disclosed intense haze and inflammation at the interface and clusters of hyperreflective round structures resembling epithelial cells within the interface area. No signs of hyphae-like structures were seen. Late-onset symptoms misled us into a bacterial chronic endophthalmitis diagnosis, and the patient was started on topical and systemic antibiotics. Despite intense antibiotic therapy, the patient developed severe endophthalmitis, so we performed anterior vitrectomy and the donor lenticule was removed. Microbiology results from the removed lenticule showed infection by C albicans. Antifungal therapy with systemic and topical voriconazole controlled the infection. CONCLUSIONS Candida interface keratitis is possible after DSAEK. The posterior location of infected tissue poses diagnostic and therapeutic challenges. In our case, the late onset of the symptoms and not performing corneoscleral rim cultures delayed correct diagnosis. This is the first reported case of post-DSAEK Candida keratitis with confocal microscopy images. A hyperintense granular deposit was seen at the lenticule and interface with confocal microscopy. We also observed intense haze, granular round structures resembling epithelial cells, and hyperreflective needle-shaped material at the interface. No hyphae-like structures were seen with confocal imaging.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The clinical characteristics of fungal keratitis in eyes after Descemet’s stripping and automated endothelial keratoplasty

The purpose of this study was to describe the clinical characteristics of fungal keratitis caused by Candida albicans in an eye after Descemet stripping automated endothelial keratoplasty (DSAEK). A 72-year-old male with a history of three trabeculectomies, cataract surgery, and two DSAEK procedures developed a corneal ulcer in his right eye two years after his last DSAEK. Fungal keratitis was ...

متن کامل

Methicillin-Resistant Staphylococcus aureus Keratitis after Descemet's Stripping Automated Endothelial Keratoplasty

PURPOSE We report a case of methicillin-resistant Staphylococcus aureus (MRSA) keratitis after Descemet's stripping automated endothelial keratoplasty (DSAEK). CASE REPORT An 87-year-old woman who had undergone a DSAEK 4 months previously was referred to Tokushima University Hospital with a diagnosis of infectious keratitis after DSAEK. A white abscess and infiltration in the inferior cornea ...

متن کامل

First Reported Case of Donor Related Candida Endophthalmitis after Descemet Membrane Endothelial Keratoplasty

PURPOSE To report the first case of Candida donor to host transmission following descemet membrane endothelial keratoplasty (DMEK). METHODS A retrospective case report. RESULTS A patient underwent uneventful DMEK. Following surgery the donor rim was culture positive for Candida. The patient developed fungal endophthalmitis that was treated medically with multiple injections of voriconazole ...

متن کامل

Deep vein thrombosis following descemet stripping automated endothelial keratoplasty.

DeepVein Thrombosis FollowingDescemet Stripping Automated Endothelial Keratoplasty Venous thromboembolism is the secondmost commonmedical complication after surgery.1 The risk factors for development of deepvein thrombosis (DVT) include age, obesity, and diabetesmellitus.1Deepvein thrombosis associatedwithophthalmic surgery, specifically vitreoretinal surgery, has been reported.2 Descemet strip...

متن کامل

Author’s response to reviews Title: Spontaneous Reattachment of Dislocated Endothelial Graft After non-Descemet Stripping Automated Endothelial Keratoplasty: A Case Report

Title: Spontaneous Reattachment of Dislocated Endothelial Graft After non-Descemet Stripping Automated Endothelial Keratoplasty: A Case Report Authors: Aya Kodama-Takahashi ([email protected]) Masahiko Fukuda ([email protected]) Koji Sugioka ([email protected]) Akira Kobayashi ([email protected]) Yoshikazu Shimomura ([email protected]) Version: 1 Date: 21 Dec 2017 Au...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of ophthalmology

دوره 21 4  شماره 

صفحات  -

تاریخ انتشار 2011