[First results with a resorbable MgYREZr compression screw in unstable scaphoid fractures show extensive bone cysts].

نویسندگان

  • Reinhard Meier
  • Martin Panzica
چکیده

Osteosynthesis with headless compression screws is an established treatment option for unstable scaphoid fractures. Common implants are made of titanium alloy or steel and usually remain in place. Due to implant density and ferromagnetic properties, artefacts are common in postoperative imaging procedures, e.g. MRI. Now resorbable implants made of magnesium alloy (MgYREZr) have become available. They have biomechanical properties equivalent to human bone and may be used as an alternative to the nonresorbable screw systems.5 patients with acute scaphoid fractures were treated with a double-threaded screw made of MgYREZr. The fractures included three type A2 fractures, one type B2 fracture, and one type B3 fracture. All patients underwent clinical and radiological follow-up postoperatively, 6 weeks, 3 and 6 months and 1 year after surgery. ROM, gross grip strength and pain (VAS) were documented. The Modified Mayo Wrist Score was used. Standard X-rays of the wrist were taken preoperatively and at all follow-up visits. A CT scan was performed at least before and three months after surgery. In all X-rays malunion, resorption of the implant, implant loosening, cysts and bone healing (bridging trabecular structures) were described.All patients had a very good wrist score (95-100 points) after one year. There were no clinical complications. However, the X-rays revealed extensive resorption cysts in 3 out of the 5 patients. It was only after 6 months that the fractures were consolidated enough to allow physical work. Due to this considerable osteolysis, we did not include any further patients. Due to the observed extensive bone cysts and the long time period for bone healing, MgYREZr compression screws are currently not recommended for clinical use in scaphoid fractures. Further fundamental research is necessary.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Treatment of scaphoid waist fractures with the HCS screw

The aim of the study was to evaluate the clinical results of the Headless Compression Screw (HCS, Synthes) when used for treatment of acute scaphoid waist fractures. The new screw design generates interfragmentary compression with use of a compression sleeve. Twenty-one patients were treated for acute scaphoid waist fractures type B2 with HCS screws. The average time to the final follow-up exam...

متن کامل

Imaging and treatment of scaphoid fractures and their complications.

The scaphoid is the most commonly fractured carpal bone, with frequent complications that are predisposed by its anatomical location, anatomical configuration (shape and length), and vascular supply. The most common mechanism of injury is a fall onto an outstretched hand. Imaging plays a significant role in the initial evaluation and treatment of scaphoid fractures and their complications. Radi...

متن کامل

Scaphoid Fracture Fixation with an Acutrak® Screw

We report a case of fixation of a scaphoid fracture using an Acutrak(®) screw. This screw is cannulated and headless, which allows it to be implanted below the surface of the bone. It uses the same concept of variable thread pitch as the Herbert screw, but unlike the Herbert screw, is fully threaded, with continuously varying pitch along its length. This variable pitch creates constant compress...

متن کامل

Comparison of Five Headless Screws for Fixation of Small Bones

Headless screws are favored for internal fixation in the treatment of displaced or unstable small bone (e.g., Scaphoid) fractures, because they are embedded below the articular surface of the bone, reducing tissue irritation and immobilization. Compression plays an important role in fracture stability, maintaining gap reduction and also accelerating the healing of cancellous bone [1]. There are...

متن کامل

Rotational Stability of Scaphoid Osteosyntheses: An In Vitro Comparison of Small Fragment Cannulated Screws to Novel Bone Screw Sets

BACKGROUND The current standard of care for operative repair of scaphoid fractures involves reduction and internal fixation with a single headless compression screw. However, a compression screw in isolation does not necessarily control rotational stability at a fracture or nonunion site. The single screw provides rotational control through friction and bone interdigitation from compression at ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Handchirurgie, Mikrochirurgie, plastische Chirurgie : Organ der Deutschsprachigen Arbeitsgemeinschaft fur Handchirurgie : Organ der Deutschsprachigen Arbeitsgemeinschaft fur Mikrochirurgie der Peripheren Nerven und Gefasse : Organ der V...

دوره 49 3  شماره 

صفحات  -

تاریخ انتشار 2017