Comparison of different approaches for optimization of atrioventricular and interventricular delay in biventricular pacing.
نویسندگان
چکیده
AIMS It has been shown that optimizing atrioventricular (AV) and interventricular (VV) delay improves cardiac performance in patients with biventricular pacemakers. However, there is no standard method for optimization available yet. The aim of this study was to compare echocardiographic parameters-displacement imaging, A wave duration, and aortic velocity time integral (VTI)-and acoustic cardiography derived electromechanical activation time (EMAT) using different approaches of AV and VV delay optimization. We tested whether the initial optimization of the AV interval followed by VV optimization at that optimal AV interval or initial optimization of the VV interval followed by AV optimization at the determined optimal VV interval was accurate and consistent, and how this compared to testing every conceivable combination of AV and VV intervals available. METHODS AND RESULTS A group of 20 patients with biventricular pacemakers was included. Displacement imaging, A wave duration, and aortic VTI were determined at different combinations of AV (100, 150, 200, 250 ms) and VV (RV40, 0, LV40 ms) intervals. If AV duration was determined first, displacement imaging identified the best setting in 8/20, aortic VTI in 10/20, A duration in 13/20, and EMAT in 18/20 patients. With VV duration determined first, the best setting was more difficult to identify regardless of the method used. There was a poor agreement in optimal AV and VV delays of the different methods, and there was no single patient in whom all four methods yielded the same delay combination. CONCLUSION It is advisable to measure a full grid of AV and VV delays to identify optimal settings rather than optimizing one of the two delays first. Different techniques for delay optimization resulted in different optimal delay combinations.
منابع مشابه
Atrioventricular and interventricular delay optimization and response quantification in biventricular pacing: arrival of reliable clinical algorithms and research protocols, and how to distinguish them from unreliable counterparts.
In this issue of the journal, Bogaard et al. assess the achievable haemodynamic increment within individuals of optimizing atrioventricular (AV) and interventricular (VV) delays. Biventricular pacing, or cardiac resynchronization therapy (CRT), arguably the greatest advancement in the treatment of heart failure in the last decade, causes immediate increases in haemodynamics and then improvement...
متن کاملNon-invasive Determination of the Optimized Atrioventricular Delay in Patients with Implanted Biventricular Pacing Devices
BACKGROUND Biventricular (BiV) is extensively used in the treatment of congestive heart failure but so far no recommendations for optimized programming of atrioventricular-delay (AVD) settings have been proposed. Can AVD optimization be performed using a simple formula based on non-invasive doppler-echocardiography? METHODS 25 patients (ejection fraction 30+/-8%) received BiV ICDs. Doppler-ec...
متن کاملOptimization of cardiac resynchronization guided by Doppler echocardiography: haemodynamic improvement and intraindividual variability with different pacing configurations and atrioventricular delays.
AIMS Cardiac resynchronization therapy (CRT) improves symptoms in heart failure patients with intraventricular conduction delay (IVCD). Different pacing modalities produce variable activation patterns and are likely to result in different haemodynamic changes. The objective of this study was to demonstrate acute haemodynamic changes with different CRT configurations. METHODS AND RESULTS In 26...
متن کاملLeft Ventricular Synchrony and Function in Pediatric Patients with Definitive Pacemakers
BACKGROUND Chronic right ventricular pacing (RVP) induces a dyssynchronous contraction pattern,producing interventricular and intraventricular asynchrony. Many studies have shown the relationship of RVP with impaired left ventricular (LV) form and function. OBJECTIVE The aim of this study was to evaluate LV synchrony and function in pediatric patients receiving RVP in comparison with those re...
متن کاملVectorcardiography as a tool for easy optimization of cardiac resynchronization therapy in canine left bundle branch block hearts.
BACKGROUND In cardiac resynchronization therapy (CRT), optimization of left ventricular (LV) stimulation timing is often time consuming. We hypothesized that the QRS vector in the vectorcardiogram (VCG) reflects electric interventricular dyssynchrony, and that the QRS vector amplitude (VAQRS), halfway between that during left bundle branch block (LBBB) and LV pacing, reflects optimal resynchron...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology
دوره 10 3 شماره
صفحات -
تاریخ انتشار 2008