Effect of Chlamydia pneumoniae infection on coronary flow reserve and intimal hyperplasia after stent implantation in patients with angina pectoris.

نویسندگان

  • T Tanaka
  • M Matsushita
  • Y Oka
  • T Sada
  • Y Kira
چکیده

OBJECTIVES Chlamydia pneumoniae (C. pneumoniae) has been detected in tissue from coronary atherosclerotic vascular lesions and may be involved in the pathogenesis of atherosclerosis. However, the effect of prior C. pneumoniae infection on coronary intimal hyperplasia after stent implantation and on coronary microvascular function is unknown. METHODS Seventy-three patients with stable angina pectoris and a single de novo coronary lesion were studied prospectively. All patients underwent successful coronary angioplasty and stent implantation for the stenotic lesion. Blood samples were tested for prior C. pneumoniae infection before the procedure, and patients were divided into two groups: Seropositive and seronegative. Coronary flow reserve was measured in the non-stenotic coronary vessel before angioplasty, and quantitative coronary arteriography was performed at the stent implantation site before angioplasty and 6 months later in all patients. RESULTS Coronary flow reserve in the non-stenotic vessel was significantly lower in the seropositive group than in the seronegative group (2.51 +/- 0.35 vs 2.76 +/- 0.43, p < 0.05). The minimum luminal diameter was smaller and late loss was greater in the seropositive group than in the seronegative group (minimum luminal diameter: 1.52 +/- 0.59 vs 1.91 +/- 0.79 mm, p < 0.05, late loss: 1.17 +/- 0.55 vs 0.76 +/- 0.67, p < 0.05). However, there was no significant difference in the restenosis rate or target lesion revascularization rate between the two groups. CONCLUSIONS Prior C. pneumoniae infection may accelerate intimal hyperplasia after stent implantation and impair coronary microvascular function in the non-stenotic coronary vessels.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Lack of association between Chlamydia Pneumoniae serology and endothelial dysfunction of coronary arteries

BACKGROUND Recent publications brought up the hypothesis that an infection with Chlamydia Pneumoniae (CP) might be a major cause of coronary artery disease (CAD). Therefore, we investigated whether endothelial dysfunction (ED) as a precursor of atherosclerosis might be detectable in patients with previous infection with CP but without angiographic evidence of CAD. METHODS We included 16 patie...

متن کامل

Lower Level of Low Density Lipoprotein Cholesterol is Associated with a Higher Increase in the Fractional Flow Reserve in Patients with Fixed-dose Rosuvastatin

AIM Fractional flow reserve (FFR) reflects on the diffuse atherosclerosis per coronary artery. It is unknown whether the statin therapy affects long term FFR after stenting. The aim of this study was to evaluate the long term FFR after stent implantation in patients who are intaking fixed-dose rosuvastatin. METHODS A total of 22 patients with stable angina pectoris were enrolled. The values o...

متن کامل

Influence of a pressure gradient distal to implanted bare-metal stent on in-stent restenosis after percutaneous coronary intervention.

BACKGROUND Fractional flow reserve predicts cardiac events after coronary stent implantation. The aim of the present study was to assess the 9-month angiographic in-stent restenosis rate in the setting of optimal stenting and a persisting gradient distal to the stent as assessed by a pressure wire pullback recording in the entire length of the artery. METHODS AND RESULTS In 98 patients with a...

متن کامل

Cytomegalovirus, Chlamydia pneumoniae, and Helicobacter pylori IgG antibodies and restenosis after stent implantation: an angiographic and intravascular ultrasound study.

OBJECTIVE To determine the impact of previous infection with cytomegalovirus, Chlamydia pneumoniae, and Helicobacter pylori on neointimal proliferation after coronary angioplasty with stent implantation. DESIGN The study population was made up of 180 patients who had stent implantation in a native coronary artery with systematic angiographic and intravascular ultrasound (IVUS) follow up at si...

متن کامل

Safety, Efficacy and Clinical Outcome of Direct Stent Implantation

Conventional methods of stenting require predilatation, which potentially increase vessel wall injury and cost of the procedure. In this study, the safety and efficacy of direct AVE-S7 (Medtronic-USA) stent placement were evaluated in 100 patients. Quantitative coronary angiography was performed at the baseline and post-stent. Clinical follow-up was done up to 9 months. In 100 patients (76 male...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cardiology

دوره 38 6  شماره 

صفحات  -