Visual performance after correcting higher order aberrations in keratoconic eyes.

نویسندگان

  • Ramkumar Sabesan
  • Geunyoung Yoon
چکیده

Keratoconic eyes are affected by an irregular optical blur induced by significant magnitude of higher order aberrations (HOAs). Although it is expected that correction of ocular aberrations leads to an improvement in visual performance, keratoconic eyes might not achieve the visual benefit predicted by optical theory because of long-term adaptation to poor retinal image quality. To investigate this, an adaptive optics (AO) system equipped with a large-stroke deformable mirror and a Shack-Hartmann wavefront sensor was used to correct the aberrations and measure high contrast tumbling E visual acuity (HCVA) in 8 keratoconic eyes. Eight normal eyes were employed as control. Aberrations were dynamically corrected with closed-loop AO during visual acuity testing, with residual root-mean-square error of around 0.1 microm in both groups over 6-mm pupil (p = 0.11). With AO correction, the HCVA in logMAR was -0.26 +/- 0.063 in normal eyes, and in keratoconic eyes, it was -0.07 +/- 0.051 (p = 0.0001) for the same pupil size. There was no correlation in the AO-corrected HCVA for normals with the magnitudes of their native HOA. However, within keratoconic eyes, poorer AO-corrected HCVA was observed with an increase of the native magnitudes of HOA (R(2) = 0.67). This may indicate that long-term visual experience with poor retinal image quality, induced by HOA, may restrict the visual benefit achievable immediately after correction in keratoconic eyes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Vision improvement by correcting higher-order aberrations with customized soft contact lenses in keratoconic eyes.

Higher-order aberration correction in abnormal eyes can result in significant vision improvement, especially in eyes with abnormal corneas. Customized optics such as phase plates and customized contact lenses are one of the most practical, nonsurgical ways to correct these ocular higher-order aberrations. We demonstrate the feasibility of correcting higher-order aberrations and improving visual...

متن کامل

Correcting highly aberrated eyes using large-stroke adaptive optics.

PURPOSE To investigate the optical performance of a large-stroke deformable mirror in correcting large aberrations in highly aberrated eyes. METHODS A large-stroke deformable mirror (Mirao 52D; Imagine Eyes) and a Shack-Hartmann wavefront sensor were used in an adaptive optics system. Closed-loop correction of the static aberrations of a phase plate designed for an advanced keratoconic eye wa...

متن کامل

Uncorrected wavefront error and visual performance during RGP wear in keratoconus.

PURPOSE To examine the relationship between uncorrected residual wavefront error and visual performance (VP) in rigid gas permeable (RGP) contact lens-wearing keratoconic eyes. METHODS Seven eyes from six subjects (six moderate, one severe) were studied (mean +/- SD age: 42.71 +/- 11.38 years). Significant corneal scarring was an exclusion criterion. Measurements were taken with RGP lenses in...

متن کامل

Visual benefit of correcting higher order aberrations of the eye.

There is currently considerable debate concerning the visual impact of correcting the higher order aberrations of the eye. We describe new measurements of a large population of human eyes and compute the visual benefit of correcting higher order aberrations. We also describe the increase in contrast sensitivity when higher order aberrations are corrected with an adaptive optics system. All thes...

متن کامل

Vision improvement by correcting higher-order aberrations with phase plates in normal eyes.

PURPOSE To psychophysically demonstrate vision improvement when correcting higher-order aberrations with phase plates in normal eyes. METHODS The wavefront aberrations of three nonsurgical normal eyes were measured with a Shack-Hartmann wavefront sensor. With these measured aberrations, phase plates were fabricated using a lathing technique. Theoretical improvement in retinal image quality wa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of vision

دوره 9 5  شماره 

صفحات  -

تاریخ انتشار 2009