We report on the design of high order mode (HOM) couplers developed for superconducting (SC) 3 harmonic cavities carried out in the framework of the SUPER 3HC project. The high damping requirements for both longitudinal and transverse modes can be achieved with the appropriate HOM dampers. The results of measurements on a copper model as well as simulations are presented.
منابع مشابه
HOM/LOM Coupler Study for the ILC Crab Cavity*
The FNAL 9-cell 3.9GHz deflecting mode cavity designed for the CKM experiment was chosen as the baseline design for the ILC BDS crab cavity. The full 9cell CKM cavity including the coupler end-groups was simulated using the parallel eigensolver Omega3P and scattering parameter solver S3P. It was found that both the notch filters for the HOM/LOM couplers are very sensitive to the notch gap, whic...
متن کاملThe Super-3hc Project: an Idle Superconducting Harmonic Cavity for Bunch Length Manipulation
In both ELETTRA and Swiss Light Source (SLS) it is planned to implement a 3 harmonic (1.5 GHz) RF system in order to lengthen the bunches and consequently improve the beam lifetime. Since their boundary conditions were rather similar, the two laboratories decided to search for a common approach. The chosen solution is the use of an idle superconducting (sc) system based on a “scaling to 1.5 GHz...
متن کامل800MHz CRAB CAVITY CONCEPTUAL DESIGN FOR THE LHC UPGRADE*
Abstract In this paper, we present an 800 MHz crab cavity conceptual design for the LHC upgrade. The cell shape is optimized for lower maximum peak surface fields as well as higher transverse R/Q. A compact coax-to-coax coupler scheme is proposed to damp the LOM/SOM modes. A two-stub antenna with a notch filter is used as the HOM coupler to damp the HOM modes in the horizontal plane and rejects...
متن کاملDisk-type Input Coupler with a Hom Damper for the Pls Storage Ring Cavity
A disk-type input coupler for the Pohang Light Source (PLS) storage ring cavity was fabricated and tested up to 60 kW. A coaxial adapter is required for this system which should have an exit for the loop coupling tubes. Since this input coupler can extract HOMs better than the cylinder-type one out of the cavity, a specially designed HOM absorber was implemented in the design of the adapter. A ...
متن کاملHigh Precision Sc Cavity Diagnostics with Hom Measurements
Experiments at the FLASH linac at DESY have demonstrated that the Higher Order Modes induced in Superconducting Cavities can be used to provide a variety of beam and cavity diagnostics. The centers of the cavities can be determined from the beam orbit which produces minimum power in the dipole HOM modes. The phase and amplitude of the dipole modes can be used as a high resolution beam position ...
متن کامل