Modified femoral pressuriser generates a longer lasting high pressure during cement pressurisation

نویسندگان

  • Jian-Sheng Wang
  • Göran Garellick
  • Fred Kjellson
  • Elizabeth Tanner
  • Gunnar Flivik
چکیده

BACKGROUND The strength of the cement-bone interface in hip arthroplasty is strongly related to cement penetration into the bone. A modified femoral pressuriser has been investigated, designed for closer fitting into the femoral opening to generate higher and more constant cement pressure compared to a commercial (conventional) design. METHODS Femoral cementation was performed in 10 Sawbones® models, five using the modified pressuriser and five using a current commercial pressuriser as a control. Pressure during the cementation was recorded at the proximal and distal regions of the femoral implant. The peak pressure and the pressure-time curves were analysed by student's t-test and Two way ANOVA. RESULTS The modified pressuriser showed significantly and substantially longer durations at higher cementation pressures and slightly, although not statistically, higher peak pressures compared to the conventional pressuriser. The modified pressuriser also produced more controlled cement leakage. CONCLUSION The modified pressuriser generates longer higher pressure durations in the femoral model. This design modification may enhance cement penetration into cancellous bone and could improve femoral cementation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Socket design and cement pressurisation in the Charnley low-friction arthroplasty.

An experimental evaluation was made of the efficacy of an unflanged cup, an ogee-flanged cup and the Exeter pressuriser in the pressurisation of acetabular cement. Only a very modest injection pressure could be generated through an unflanged socket and even this was readily lost as the socket "bottomed out". The ogee-flanged socket gave a consistently high injection pressure which could be main...

متن کامل

Comparison of two pressurisers for cementation of the proximal femur.

PURPOSE To compare pressures generated by 2 different cement pressurisers at various locations in the proximal femur. METHODS Two groups of 5 synthetic femurs were used, and 6 pressure sensors were placed in the femur at 20-mm intervals proximally to distally. Cement was filled into the femoral canal retrogradely using a cement gun with either the half-moon pressuriser or the femoral canal pr...

متن کامل

The role of methylmethacrylate monomer in the formation and haemodynamic outcome of pulmonary fat emboli.

We examined the roles of methylmethacrylate (MMA) monomer and cementing technique in the formation, and haemodynamic outcome, of pulmonary fat emboli. The preparation of the femoral canal and the cementing technique were studied in four groups of adult dogs as follows: control (no preparation); lavage; cement pressurisation; and cement pressurisation after lavage. We measured the intramedullary...

متن کامل

An in Vitro Comparative Study of the Performance of Different Commercially Available Intramedullary Femoral Plugs during Total Hip Replacement

Distal flow of polymethylmethacrylate (PMMA) bone cement during insertion of the femoral implant results in reduced pressure and cement-bone interdigitation (Markolf, Amstutz, 1976). Insertion of femoral cement plugs in the intramedullary canal to prevent distal flow of PMMA cement in total hip replacement during cementing of femoral prostheses is well accepted and has become current practice (...

متن کامل

Cement pressurisation during hip replacement.

The newer techniques of cementing aim to improve interlock between cement and bone around a femoral stem by combining high pressure and reduced viscosity. This may produce increased embolisation of fat and marrow leading to hypotension, impaired pulmonary gas exchange and death. For this reason the use of high pressures has been questioned. We compared finger-packing with the use of a cement gu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2011