Radiation Exposure to the Hand of a Spinal Interventionalist during Fluoroscopically Guided Procedures

نویسندگان

  • Kazuta Yamashita
  • Hisanori Ikuma
  • Takuya Tokashiki
  • Takashi Maehara
  • Akihiro Nagamachi
  • Yoichiro Takata
  • Toshinori Sakai
  • Kosaku Higashino
  • Koichi Sairyo
چکیده

STUDY DESIGN Prospective study. PURPOSE During fluoroscopically guided spinal procedure, the hands of spinal surgeons are placed close to the field of radiation and may be exposed to ionizing radiation. This study directly measured the radiation exposure to the hand of a spinal interventionalist during fluoroscopically guided procedures. OVERVIEW OF LITERATURE Fluoroscopically guided spinal procedures have been reported to be a cause for concern due to the radiation exposure to which their operators are exposed. METHODS This prospective study evaluated the radiation exposure of the hand of one spinal interventionalist during 52 consecutive fluoroscopic spinal procedures over a 3-month period. The interventionalist wore three real-time dosimeters secured to the right forearm, under the lead apron over the chest, and outside the lead apron over the chest. Additionally, one radiophotoluminescence glass dosimeter was placed under the lead apron over the left chest and one ring radiophotoluminescence glass dosimeter was worn on the right thumb. The duration of exposure and radiation dose were measured for each procedure. RESULTS The average radiation exposure dose per procedure was 14.9 µSv, 125.6 µSv, and 200.1 µSv, inside the lead apron over the chest, outside the lead apron over the chest, and on the right forearm, respectively. Over the 3-month period, the protected radiophotoluminescence glass dosimeter over the left chest recorded less than the minimum reportable dose, whereas the radiophotoluminescence glass ring dosimeter recorded 368 mSv for the thumb. CONCLUSIONS Our findings indicated that the cumulative radiation dose measured at the dominant hand may exceed the annual dose limit specified by the International Commission on Radiological Protection. Spinal interventionalists should take special care to limit the duration of fluoroscopy and radiation exposure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiation exposure to the physician performing fluoroscopically guided caudal epidural steroid injections.

This study was designed to investigate radiation exposure to a physician performing fluoroscopically guided caudal epidural steroid injections. The prospective study design included 100 consecutive fluoroscopically guided caudal epidural steroid injections performed on patients with radiculitis from either herniated nucleus pulposus or lumbar spinal stenosis. Radiation exposure was monitored wi...

متن کامل

Surgeon and patient radiation exposure in minimally invasive transforaminal lumbar interbody fusion.

OBJECT Minimally invasive transforaminal lumbar interbody fusion (TLIF) is an increasingly popular procedure. The technique involves use of fluoroscopy to assist with pedicle screw (PS) placement. The potential exists for both the surgeon and the patient to become exposed to significant amounts of radiation. The authors undertook this study to quantify the radiation dose to the surgeon and pati...

متن کامل

Ulcerated Radiodermatitis Induced after Fluoroscopically Guided Stent Implantation Angioplasty

Cases of radiation-induced skin injury after fluoroscopically guided procedures have been reported since 1996, though the majority of them have been published in Radiology and Cardiology literature, less frequently in Dermatology journals. Chronic radiation dermatitis induced by fluoroscopy can be difficult to diagnose; a high grade of suspicion is required. We report a case of an obese 46-year...

متن کامل

Perioperative radiation exposure in a pregnant woman

The perioperative imaging of a pregnant woman presents a unique challenge to orthopaedics surgeon as concern about the radiation risk to the embryo or fetus. This article highlights effect of radiation exposure on foetus.I would like to discuss about the amount of radiation exposure in a pregnant woman during fluoroscopic guided closed femoral Interlock nailing as radiation has significant...

متن کامل

Preventing Patient Death or Serious Injury Associated With Radiation Exposure From Fluoroscopy and Computed Tomography: Brief Review (NEW) - Making Health Care Safer II - NCBI Bookshelf

Effects associated with radiation can be categorized as either deterministic or stochastic. Deterministic effects manifest themselves in a relatively short time after a high-intensity exposure to radiation (e.g., 1 or more sieverts). In 1994, approximately 50 radiation-induced burns were reported to the U.S. Food and Drug Administration (FDA). In 2000, a review of 73 reports of radiation-induce...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2017