A method for the standardized offline collection of exhaled nitric oxide.

نویسندگان

  • P E Silkoff
  • A Stevens
  • J Pak
  • B Bucher-Bartelson
  • R J Martin
چکیده

STUDY OBJECTIVES Exhaled nitric oxide (ENO) is a noninvasive marker of airway inflammation. The purpose of this study was to compare a standardized offline ENO measurement apparatus with a validated on-line method. DESIGN Asthmatic volunteers (n = 21) had ENO measured by the two following methods: (1) inhalation to total lung capacity (TLC) followed by exhalation at a constant flow (45 mL/s) against a high resistance, while monitoring nitric oxide (NO) and pressure on-line; and (2) inhalation to TLC and exhalation into mylar balloons via an apparatus that included the same resistance and flow rate as used in the on-line method. We also examined NO stability in mylar balloons over 48 h. MEASUREMENTS AND RESULTS ENO values (given as geometric mean in parts per billion [ppb]; 95% confidence intervals) differed between the on-line method (69.6; 42.6 to 113.8) and the offline method (49.5; 30.9 to 79.3), indicating that the offline method gave lower ENO measures than the on-line method (p < 0.001). Furthermore, this difference between measures increased with increasing mean values. The intraclass correlation coefficient (0.931), however, showed excellent correlation between the on-line and offline methods. Within-subject repeatability, as assessed by the coefficient of repeatability (CR), was good for both the on-line and offline methods (CR, 1.09 and 1.17, respectively). Geometric mean NO concentrations (95% confidence limits) in mylar balloons containing exhalate increased from a baseline of 55.8 ppb (36.9, 84.4) to 64.5 ppb (45.6, 91.1) and 69.5 ppb (51.4, 94.0) at 24 h and 48 h, respectively. CONCLUSIONS The offline method gave reproducible ENO values that were consistently smaller than, but showed good correlation with, values obtained with on-line ENO collection. This method is suitable for offline collection, but the measured values are not interchangeable with those obtained by on-line measurement.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ATS/ERS recommendations for standardized procedures for the online and offline measurement of exhaled lower respiratory nitric oxide and nasal nitric oxide, 2005.

History of This Document Section 1: Background Assessment of Airway Inflammation Exhaled NO Nasal NO Section 2: Recommendations for a Standardized Procedure for the Online Measurement of Exhaled NO in Adults Requirements for the Clinical Use of Exhaled NO Measurements Standardization of Exhaled NO Terminology and Units General Principles Regarding Exhaled NO Measurement Non–Disease-related Pati...

متن کامل

American Thoracic Society Documents ATS/ERS Recommendations for Standardized Procedures for the Online and Offline Measurement of Exhaled Lower Respiratory Nitric Oxide and Nasal

History of This Document Section 1: Background Assessment of Airway Inflammation Exhaled NO Nasal NO Section 2: Recommendations for a Standardized Procedure for the Online Measurement of Exhaled NO in Adults Requirements for the Clinical Use of Exhaled NO Measurements Standardization of Exhaled NO Terminology and Units General Principles Regarding Exhaled NO Measurement Non–Disease-related Pati...

متن کامل

American Thoracic Society Documents ATS/ERS Recommendations for Standardized Procedures for the Online and Offline Measurement of Exhaled Lower Respiratory Nitric Oxide and Nasal

History of This Document Section 1: Background Assessment of Airway Inflammation Exhaled NO Nasal NO Section 2: Recommendations for a Standardized Procedure for the Online Measurement of Exhaled NO in Adults Requirements for the Clinical Use of Exhaled NO Measurements Standardization of Exhaled NO Terminology and Units General Principles Regarding Exhaled NO Measurement Non–Disease-related Pati...

متن کامل

Will use of exhaled breath condensate be useful for the intensive care unit routine?

Endogenous production of nitric oxide can be detected and monitored in exhaled air of men and animals. The main objective of this review was to discuss if nitric oxide in exhaled breath condensate is a useful tool when investigating respiratory dysfunctions in intensive care units. Specialized literature reveals an increasing interest in the use of exhaled breath condensate as a non-invasive me...

متن کامل

Off-line sampling of exhaled air for nitric oxide measurement in children: methodological aspects.

Measurement of nitric oxide in exhaled air is a noninvasive method to assess airway inflammation in asthma. This study was undertaken to establish the reference range of exhaled NO in healthy school-aged children and to determine the influence of ambient NO, noseclip and breath-holding on exhaled NO, using an off-line balloon sampling method. All children attending a primary school (age range 8...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Chest

دوره 116 3  شماره 

صفحات  -

تاریخ انتشار 1999