Gas-liquid chromatography: the gas-density meter, a new apparatus for the detection of vaporus in flowing gas streams.
نویسندگان
چکیده
The separation of volatile substances by gasliquid chromatography (James & Martin, 1952; James, Martin & Smith, 1952; James, 1952; James & Martin, 1954; Ray, 1954a, b) requires that the substances be detected as they leave the chromatogram in the stream of gas that acts as the mobile phase of the system. A number of methods of detection of varying sensitivity have already been developed (James & Martin, 1952; Ray, 1954a; Griffiths, James & Phillips, 1952; Griffiths & Phillips, 1954), but we have felt it important to use a detector of high sensitivity whose response was independent of the chemical structure of the substances being separated. From many points of view measurement of the density of the gas stream emerging from the chromatogram is attractive, since response is dependent on the molecular-weight differences of gab and vapour only, and calibration is relatively simple. Claesson (1946) has described an apparatus for comparing the density of a standard gas and that issuing from a chromatogram in which a liquid manometer is used to detect pressure differences between columns of gas 6 ft. long. The sensitivity of this apparatus suffices only for measuring the high concentrations encountered in displacement analysis. The pressure differences due to the flow of gas were kept very small by the use of large-diameter tubes; this resulted in the volume of the apparatus being very large. In the design of an instrument based on the same principle (the gas-density meter) we have compensated for the pressure difference 'due to flow by employing tubes arranged as a bridge circuit in which two points can be found, vertically displaced from one another, where the pressure difference is independent of the rate of flow of gas. It is possible to combine two such bridges in one of which chromatogram gas flows and in the other a reference stream, so that the difference in head due to the density difference of the two gases is directly measurable.
منابع مشابه
Effect of Nondimensional Parameters On the Internal Circulation of a Liquid Drop Moving with the Surrounding Gas
The internal flow circulation dynamics of a liquid drop moving in a co- or counter-flowing gas stream has been numerically studied. The present work is concerned with the time accurate numerical solution of the two phase flow field at the low Mach number limit with an appropriate volume tracking method to capture motion and deformation of a liquid drop. It is shown that relative velocity betwee...
متن کاملEffect of Nondimensional Parameters On the Internal Circulation of a Liquid Drop Moving with the Surrounding Gas
The internal flow circulation dynamics of a liquid drop moving in a co- or counter-flowing gas stream has been numerically studied. The present work is concerned with the time accurate numerical solution of the two phase flow field at the low Mach number limit with an appropriate volume tracking method to capture motion and deformation of a liquid drop. It is shown that relative velocity betwee...
متن کاملDetermination of 2-phenylethanol in Rose Water Using Dispersive Liquid-Liquid Microextraction with Gas Chromatography Flame Ionization Detection
A simple and rapid microextraction procedure based on dispersive liquid-liquid microextraction (DLLME) coupled with gas chromatography-flame ionization detection (GC-FID) was developed for the extraction and analysis of 2-phenylethanol in rose water sample. In the proposed approach, carbon tetrachloride and ethanol were used as extraction and dispersive solvents, respectively. Some important pa...
متن کاملDetermination of Two Antiepileptic Drugs in Urine by Homogenous Liquid-Liquid Extraction Performed in A Narrow Tube Combined With Dispersive Liquid-liquid Microextraction Followed by Gas Chromatography-flame Ionization Detection
A simple and efficient homogenous liquid-liquid extraction method performed in a narrow tube combined with dispersive liquid-liquid microextraction method has been presented for the simultaneous determination of two antiepileptic drugs in urine followed by gas chromatography with flame ionization detection. In this method, a mixture of acetonitrile and urine sample (homogenous solution) is load...
متن کاملDetection and Determination of some Migrated Chemicals from Plastic Containers into Different Drinks and Liquids Using Dispersive Liquid-liquid Microextraction Prior to Gas Chromatography
Migration of chemicals from plastic containers into drinks and liquids containing them, is supposed to be a hazardous phenomenon and results in many health problems. Sample preparation is of great importance due to trace amounts analysis of these compounds. In this research, dispersive liquid–liquid microextraction is applied for the extraction and preconcentration of the migrated compounds pri...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Biochemical journal
دوره 63 1 شماره
صفحات -
تاریخ انتشار 1956