Homograft valves: is degeneration inevitable?

نویسندگان

  • E Bodnar
  • W H Wain
  • D N Ross
چکیده

Since the first successful sub-coronary insertion (Ross 1962), the homograft aortic valve has been the favourite amongst many rypes of mechanicai or biological cardiac vaive repiacements ar the National Heart Hospital. Recent srudies on long rerm patient survivai afrer homograft insertion have reveaied excelient results (Bodnar er ai 1979), surpassed oniy by the autotranspianted puimonary valves. (Ross 1967; Ross et ai 1979). Ir is generally accepted that homograft vaives inserred into the aorric position have two major advantages (Ross 1962), they are non-thrombogenic, and (Bodnar et ai 1979) their haemodynamic performance is identicai to that of a normal aortic valve. However, two major disadvanrages are often reported as weii (Ross 1962): difficuities in the coilection, preparation and storage of these vaives, and (Bodnar et ai 1979) the rapid degenerarion which affects. the function of the homograft (Stinson et ai 1977; Anderson and Hancock 1976; Lefrak and Starr 1979). An analysis of the overali performance of the homograft vaive in the aortic posirion has show satisfactory long term resuits (Bodnar et ai 1979). The present work focuses attention on the degeneration of homograft valves in terms of incidence, onser and pattern.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Homograft Crossmatching Is Unnecessary due to the Absence of Blood Group Antigens

Background. Homograft valves are subject to calcification and structural degeneration in the long term. Blood group matching is performed in many centers, and it remains controversial whether immunologic responses associated with potential blood group incompatibility contribute to the degeneration of unmatched homografts. We studied the expression of carbohydrate blood group antigens on valve e...

متن کامل

Hemograft crossmatching is unnecessary due to the absence of blood group antigens.

BACKGROUND Homograft valves are subject to calcification and structural degeneration in the long term. Blood group matching is performed in many centers, and it remains controversial whether immunologic responses associated with potential blood group incompatibility contribute to the degeneration of unmatched homografts. We studied the expression of carbohydrate blood group antigens on valve en...

متن کامل

Patient outcome and valve performance following a second aortic valve homograft replacement.

BACKGROUND Homograft valves offer many advantages; however, there is concern about their use in second aortic valve replacement because of the complexity of the procedure and the possibility of accelerated degeneration. METHODS AND RESULTS One hundred and forty-four patients underwent a second aortic homograft replacement between 1973 and 1997 (mean follow-up 6.5+/-5 years, range 1 to 20 year...

متن کامل

Aortic and mitral valve replacement in children: is there any role for biologic and bioprosthetic substitutes?

OBJECTIVE The ideal valve substitute in children does not exist. Biologic and bioprosthetic valves do not require anticoagulation, however their use is complicated by accelerated degeneration and requirement for reoperation. We examine results following mitral (MVR) or aortic (AVR) replacement with biologic and bioprosthetic valves at our institution. METHODS Medical records of children who u...

متن کامل

Post-mortem shrinkage of homograft aortic valves.

Experience has shown that some frame-mounted homograft aortic valves, although competent immediately after mounting, are incompetent when subsequently presented for surgical use. Retraction and shrinkage of the cusps appears to be the cause of this change. Clinical and experimental studies have shown that shrinkage of homograft aortic valves occurs over an approximately five-day period after de...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta medica portuguesa

دوره Suppl 1  شماره 

صفحات  -

تاریخ انتشار 1980