Conditioning prepulse of biphasic defibrillator waveforms enhances refractoriness to fibrillation wavefronts.

نویسندگان

  • J F Swartz
  • J L Jones
  • R E Jones
  • R Fletcher
چکیده

The mechanism of biphasic waveform defibrillation threshold reduction is unknown. We tested the hypothesis that, during refractory period stimulation, sarcolemmal hyperpolarization by the first pulse of biphasic waveforms facilitates excitation channel recovery, which enhances graded responses produced by the second depolarizing pulse. This prolongs cellular refractoriness to fibrillation wavefronts when compared with a monophasic depolarizing stimulus. Monophasic (10 msec, rectangular wave) or symmetrical biphasic (10 msec, each pulse) current injection S2 stimuli at 1.5 and two times S1 threshold were used to scan the S1 action potential refractory period (S1 cycle length, 600 msec) in myocardial cell aggregates. S2 waveforms were delivered with normal and reversed polarity to test the hyperpolarizing action of biphasic waveforms. Responses to an S3 stimulus, which simulated a potential incoming fibrillation wavefront, were also determined. Results showed that biphasic S2 waveforms produced longer graded responses during and immediately after the S1 refractory period than did corresponding monophasic S2 waveforms. The maximum difference in response duration produced by the biphasic and monophasic waveforms was 58.6 +/- 10.0 msec (p less than 0.001). This maximum difference occurred 10 msec before the end of the S1 refractory period. The longer response durations produced by biphasic S2 also produced longer refractoriness to the S3 stimulus. The maximum difference in total refractoriness to S3 of 51.8 +/- 2.8 msec (p less than 0.002) occurred at the same S1S2 coupling interval as the maximum difference in S2 response duration. Prolonged refractoriness may protect ventricular cells from refibrillation wavefronts and act as the cellular basis for greater biphasic waveform defibrillation efficacy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electrophysiology of ventricular fibrillation and defibrillation.

The survival rate from ventricular fibrillation is very high for short-duration fibrillation (<30 secs) but decreases to approximately 3% to 30% in out-of-hospital conditions. During short-duration fibrillation, action potentials occur rapidly with no intervening period of electrical diastole; a shock defibrillates by interacting with the fibrillation action potential to produce a uniformly lon...

متن کامل

Comparing the efficacy and safety of a novel monophasic waveform delivered by the passive implantable atrial defibrillator with biphasic waveforms in cardioversion of atrial fibrillation.

BACKGROUND The passive implantable atrial defibrillator (PIAD) (with no battery or discharging capacitor and powered transcutaneously by radio-frequency energy) delivering a novel monophasic low-tilt waveform is more efficacious than the standard monophasic waveform at atrial defibrillation. Standard biphasic (STB) waveforms, however, are more efficacious and safer than monophasic waveforms. Th...

متن کامل

Relation of atrial refractoriness to upper and lower limits of vulnerability for atrial fibrillation/flutter following implantable ventricular defibrillator shocks.

BACKGROUND Implantable ventricular cardioverter defibrillator (ICD) shocks can cause atrial fibrillation/flutter (AF). This study investigated the pathogenesis of AF after ICD shocks in a canine model. METHODS AND RESULTS The study was conducted in 8 dogs. In 5 dogs (group 1), truncated exponential (8 ms, 78% tilt) monophasic and biphasic shocks were delivered through a bipolar epicardial (pa...

متن کامل

The influence of ventricular fibrillation duration on defibrillation efficacy using biphasic waveforms in humans.

OBJECTIVES The purpose of this study was to prospectively investigate the influence of ventricular fibrillation (VF) durations of 5, 10 and 20 s on the defibrillation threshold (DFT) during implantable cardioverter-defibrillator (ICD) implantation. BACKGROUND Although the DFT using monophasic waveforms has been shown to increase with VF duration in humans, the effect of VF duration on defibri...

متن کامل

Ventricular defibrillation with triphasic waveforms.

BACKGROUND It has been reported that triphasic defibrillation waveforms cause less myocardial injury than biphasic waveforms. This study compared the defibrillation thresholds (DFTs) of triphasic and biphasic waveforms. METHODS AND RESULTS ++DFTs were determined for a transvenous lead system and a 300-microF-capacitor defibrillator. In 8 pigs (group 1), DFTs were determined for 5 triphasic wa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation research

دوره 68 2  شماره 

صفحات  -

تاریخ انتشار 1991