Comparison of alternative conducted emission measurement methods by using FSV and IELF algorithms
نویسندگان
چکیده
When performing in-situ measurements of conducted emission, it is not always possible to use a LISN (line impedance stabilisation network). This is especially the case when testing large machines, where a LISN with a high current capacity is needed. In this paper some alternative test methods are proposed to measure conducted emission. The measurements are compared to the LISN measurement and evaluated with FSV and IELF algorithms. Also two modified versions of FSV and IELF are used for further evaluation of the proposed methods.
منابع مشابه
Simultaneous Determination of Ibuprofen and Caffeine in Urine Samples by Combining MCR-ALS and Excitation-emission Data
Second order advantage of excitation-emission fluorescence matrix was applied for the simultaneous determination of ibuprofen and caffeine. The proposed method is based on the measurement of the native fluorescence and recording emission spectra of ibuprofen and caffeine in different excitation wavelengths. The mixture of these compounds was resolved by multivariate curve resolution coupled wit...
متن کاملPer Unit Coding for Combined Economic Emission Load Dispatch using Smart Algorithms
This paper proposes per unit coding for combined economic emission load dispatch problem. In the proposed coding, it is possible to apply the percent effects of elements in any number and with high accuracy in objective function. In the proposed per unit coding, each function is transformed into per unit form based on its own maximum value and has a value from 0 to 1. In this paper, particle sw...
متن کاملHydrogen and Ethanol as Potential Alternative Fuels Compared to Gasoline under Improved Exhaust Gas Recirculation
In the present study, a computational fluid dynamics (CFD) method have been utilized to investigate the effects of exhaust gas recirculation (EGR) and initial charge pressure by means of using a supercharger on the emissions and performance of a SI engine. This engine is fueled separately by gasoline and two potential alternative fuels, hydrogen and ethanol. The results of simulation are compar...
متن کاملAutomatic extraction of forward stroke volume using dynamic PET/CT: a dual-tracer and dual-scanner validation in patients with heart valve disease
BACKGROUND The aim of this study was to develop and validate an automated method for extracting forward stroke volume (FSV) using indicator dilution theory directly from dynamic positron emission tomography (PET) studies for two different tracers and scanners. METHODS 35 subjects underwent a dynamic (11)C-acetate PET scan on a Siemens Biograph TruePoint-64 PET/CT (scanner I). In addition, 10 ...
متن کاملImproving the Performance of ICA Algorithm for fMRI Simulated Data Analysis Using Temporal and Spatial Filters in the Preprocessing Phase
Introduction: The accuracy of analyzing Functional MRI (fMRI) data is usually decreases in the presence of noise and artifact sources. A common solution in for analyzing fMRI data having high noise is to use suitable preprocessing methods with the aim of data denoising. Some effects of preprocessing methods on the parametric methods such as general linear model (GLM) have previously been evalua...
متن کامل