High Efficiency R22 Replacement
نویسندگان
چکیده
منابع مشابه
Discharge Gas Temperature Control in Reciprocating Hermetic Compressors Modified for R134a/R22 Refrigerants Operation as Substitutes of Present R12/R502
Discharge gas temperature value is an indicator of compressor safe operating conditions, particularly on R12 and R502 commercial applications. These refrigerants will be replaced very soon by R134a and R22 respectively, also if R22 is not considered a final solution. High discharge temperatures are typical in LBP-R22 hermetic compressors operating at low evaporating temperature as low as -40"C;...
متن کاملOptimal Distribution of Condenser Area for Retrofits
A. 1 ohansson and P. Lundqvist Dept. of Energy Technology Div. of Applied Thennodynamics and Refrigeration The Royal Institute of Technology, KTH Stockholm, Sweden Test results from field retrofit situations, where R22 has been changed to Isceon 59 1 and R407C in two identical chillers, shows that both substitutes require more subcooling than R22 to give the system a satisfying performance. It ...
متن کاملInvestigation of Using Nonazeotropic Refrigerant Mixture as the Replacement for R12
This paper investigates the effects of nonazeotropic refrigerant mixtures (NARMs) as replacement of CFCs. The thermodynamic propert1es of NARM R22/R142b which is harmless to ozone layer are analyzed. The tests about water-to-water heat pump and dual-evaporator refrigerator-freezer using R22/R142b as alternative to R12 are introduced. The test results show R22/Rl42b is of energy conserving effec...
متن کاملComparative Exergy Analysis of Vapor Compression Refrigeration System Using Alternative Refrigerants
Abstract—In present paper, the performance of various alternative refrigerants is compared to find the substitute of R22, the widely used hydrochlorofluorocarbon refrigerant in developing countries. These include the environmentally friendly hydrofluorocarbon (HFC) refrigerants such as R134A, R410A, R407C and M20. In the present study, a steady state thermodynamic model (includes both first and...
متن کاملTesting of Environment Friendly Refrigerant R290 for Water Cooler Application (RESEARCH NOTE)
This paper presents environment friendly refrigerant R290 as a solution to the environmental concerns like depletion of ozone layer and rise in global warming because of wide use of synthetic refrigerants R22 and R134a. The water cooler is the widely used refrigeration application in warm climatic countries. Refrigerant R22 and R134a are predominantly used refrigerants in water cooler refrigera...