Simulated surgery on computed tomography and magnetic resonance images: an aid for intraoperative radiotherapy.

نویسندگان

  • M Desco
  • J López
  • F A Calvo
  • A Santos
  • J A Santos
  • F del Pozo
  • P García-Barreno
چکیده

Intraoperative radiotherapy (IORT) is a relatively new technique in which irradiation with electrons is performed during an open surgery procedure. This approach poses significant problems in obtaining accurate dosimetry, since neither the pre- nor the postoperative patient images actually matches the irradiation field. Our objective was to implement a software tool able to provide an estimate of the dose distribution, overcoming the problem of the geometrical mismatch between the images and the surgical field during the irradiation. The program was developed in the C programming language, on a noncommercial version of a Philips EasyVision workstation. The application allows to create a new data set by manipulating the preoperative computed tomography and magnetic resonance images in order to simulate the final geometry of the surgical area during the IORT procedure. The exact dose distribution can then be calculated by transferring these new images to a standard radiotherapy planning system. Also an approximate dose distribution can be quickly displayed by superimposing isodose curves obtained from a water phantom. The proposed approach introduces a helpful tool for dosimetry and planning in IORT protocols, improving their accuracy and safety and allowing for more objective quality control and patient follow-up.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Generating Synthetic Computed Tomography and Synthetic Magnetic Resonance (sMR: sT1w/sT2w) Images of the Brain Using Atlas-Based Method

Introduction: Nowadays, magnetic resonance imaging (MRI) in combination with computed-tomography (CT) is increasingly being used in radiation therapy planning. MR and CT images are applied to determine the target volume and calculate dose distribution, respectively. Since the use of these two imaging modalities causes registration uncertainty and increases department w...

متن کامل

Application of computed tomography and magnetic resonance imaging fusion images for delineating gross tumor volume in three-dimensional conformal radiotherapy of nasopharyngeal carcinoma

Background: To evaluate computed tomography (CT) and magnetic resonance imaging (MRI) fusion images for delineating gross tumor volume (GTV) in three-dimensional conformal radiotherapy (3D-CRT) of nasophanrygeal carcinoma (NPC), and compare treatment outcomes between CT- and CT+MRI-based targets. Materials and Methods: A total of 120 NPC patients treated with 3D-CRT were included, in which, 60 ...

متن کامل

Pseudo-CT Generation from Magnetic Resonance Imaging by fuzzy look up table algorithm

Introduction: Despite growing interest in the use of magnetic resonance imaging (MRI) in the external radiotherapy design process (RT), Computer Tomography (CT) remains a gold standard and is regarded as a basic imaging modality in radiotherapy. MRI shows the high contrast in soft tissues without any radiation exposure to patients. As a result, MRI is used in functional tissue ...

متن کامل

Artifacts of Titanium, Zirconium, and Binary Titanium-Zirconium Abutments in Compute Tomography, Cone Beam Computed Tomography, and Magnetic Resonance Imaging

Aim: The aim of this in vitro study was to evaluate imaging artifacts induced by Titanium, Zirconium, Titanium-Zirconium abutments in CT, MRI and CBCT imaging modalities.Methods: A 4×8mm titanium fixture was inserted in a dry human mandible. Titanium, Zirconium and Titanium–Zirconium abutments measuring 10.5 mm in height are located on the fixture, one by one. Each abutment was scan...

متن کامل

Development of an Advanced Optical Coherence Tomography System for Radiation Dosimetry

Introduction: According to the literature, optical coherence tomography (OCT) can be used measure radiation absorbed dose. This study was carried out to design a computed tomography system for the calculation of absorbed dose and optimization of dose delivery in radiotherapy using gel dosimeters. Material and Methods: An advanced charge-coupled device based OCT system was developed in laborator...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Computer aided surgery : official journal of the International Society for Computer Aided Surgery

دوره 2 6  شماره 

صفحات  -

تاریخ انتشار 1997