Impingement in total hip arthroplasty a study of retrieved acetabular components.

نویسندگان

  • Won Yong Shon
  • Todd Baldini
  • Margaret G Peterson
  • Timothy M Wright
  • Eduardo A Salvati
چکیده

Impingement can damage the acetabular liner, create polyethylene wear, and cause dislocation. We determined the prevalence of impingement, its relation with dislocation, and the influence of patient, surgical, and design factors in 162 components randomly selected from a larger group retrieved between 1990 and 1999. Impingement arc, severity, and wear damage were measured; patient data were obtained from medical records, and component position was determined from radiographs. More than half (56%) showed impingement, including 94% of those removed for dislocation. The occurrence of impingement was significantly increased if the revision diagnosis was dislocation, if the component had a large outer diameter or an elevated rim, and if the femoral component had an extended flanged neck. Implant design, in particular head/neck ratio, can help reduce the prevalence of impingement.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Notching of the femoral stem neck in metal-on-metal total hip replacement: a case report.

We report a case of impingement in a metal-on-metal total hip replacement causing both notching of the femoral stem neck and aseptic loosening of the acetabular component. The acetabular component was inserted in excessive anteversion. The femoral stem and acetabular components were retrieved. A larger femoral head was used, and an acetabular component was placed in a less anteverted position. ...

متن کامل

Factors affecting bony impingement in hip arthroplasty.

Computer modeling of 10 patients' computed tomographic scans was used to study the variables affecting hip arthroplasty range of motion before bony impingement (ROMBI) including acetabular offset and height, femoral offset, height and anteversion, and osteophyte removal. The ROMBI was compared with the ROM before component impingement and the native hip ROM. The ROMBI decreased with decreased t...

متن کامل

True Angle between Anterior-Posterior Impingement in Total Hip Arthroplasty: Why Common Constrained Cups have to Fail

Background: Dislocation after total hip arthroplasty is a common complication and partially based on impingement. Questions/purposes: (1) The purpose of this study was to investigate the angle between anterior and posterior impingement in current hip cup designs. (2) Furthermore, the aim was to design a model of an acetabular cup with sparing gaps that match to impact areas. Methods: The range ...

متن کامل

A computer model of the position of the combined component in the prevention of impingement in total hip replacement.

Dislocation remains a major concern after total hip replacement, and is often attributed to malposition of the components. The optimum position for placement of the components remains uncertain. We have attempted to identify a relatively safe zone in which movement of the hip will occur without impingement, even if one component is positioned incorrectly. A three-dimensional computer model was ...

متن کامل

Cementless Hip Arthroplasty in Southern Iran, Midterm Outcome and Comparison of Two Designs

Background: Cementless hip prosthesis was designed to provide biologic fixation, without the use of cement. The second generation components have shown more reliable bone ingrowths and survival rates. We are reporting a midterm result of two designs of cementless prosthesis in a unique culture with different social habits and expectations.Methods: 52 primary cementless total hip arthroplasty in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of arthroplasty

دوره 20 4  شماره 

صفحات  -

تاریخ انتشار 2005