Algorithm for hyperfast cone-beam spiral backprojection
نویسندگان
چکیده
Cone-beam spiral backprojection is computationally highly demanding. At first sight, the backprojection requirements are similar to those of cone-beam backprojection from circular scans such as it is performed in the widely used Feldkamp algorithm. However, there is an additional complication: the illumination of each voxel, i.e. the range of angles the voxel is seen by the X-ray cone is a complex function of the voxel position. The weight function has no analytically closed form and must be numerically determined. Storage of the weights is prohibitive since the amount of memory required equals the number of voxels per spiral rotation times the number of projections a voxel receives contributions and therefore is in the order of 10(9) to 10(11) floating point values for typical spiral scans. We propose a new algorithm that combines the spiral symmetry with the ability of today's 64 bit CPUs to store large amounts of precomputed weights. Using the spiral symmetry in this way allows to exploit data-level parallelism and thereby to achieve a very high level of vectorization. An additional postprocessing step rotates these slices back to normal images. Our new backprojection algorithm achieves up to 24.6 Giga voxel updates per second (GUPS) on our systems that are equipped with two standard Intel X5570 quad core CPUs (Intel Xeon 5500 platform, 2.93 GHz, Intel Corporation). This equals the reconstruction of 410 images per second assuming each slice consists of 512 x 512 pixels, receiving contributions from 512 projections.
منابع مشابه
Katsevich-Type Algorithms for Variable Radius Spiral Cone-Beam CT
To solve the long object problem, an exact and efficient algorithm has been recently developed by Katsevich. While the Katsevich algorithm only works with standard helical cone-beam scanning, there is an important need for nonstandard spiral cone-beam scanning. Specifically, we need a scanning spiral of variable radius for our newly proposed electron-beam CT/micro-CT prototype. In this paper, f...
متن کاملAdvanced single-slice rebinning in cone-beam spiral CT: Theoretical considerations and medical applications
The advanced single–slice rebinning algorithm (ASSR) is a highly accurate and efficient approximative algorithm for cone–beam spiral CT that a) yields high image quality even at large cone angles, b) makes use of available 2D backprojection algorithms/hardware and c) allows for sequential data processing. It uses virtual R–planes (reconstruction planes) that are tilted to optimally fit 180 spir...
متن کاملA backprojection-filtration algorithm for nonstandard spiral cone-beam CT with an n-PI-window.
For applications in bolus-chasing computed tomography (CT) angiography and electron-beam micro-CT, the backprojection-filtration (BPF) formula developed by Zou and Pan was recently generalized by Ye et al to reconstruct images from cone-beam data collected along a rather flexible scanning locus, including a nonstandard spiral. A major implication of the generalized BPF formula is that it can be...
متن کاملA Parallel Backprojection Algorithm for Spiral Cone-Beam CT Exact Reconstruction
On reconstructing a volume, the exact reconstruction algorithm for spiral cone-beam CT accesses the memory many times while all the filtered projection data has to be arrived. This is quite a bottleneck for implementation. Normally, the filtered projection data is transferred frame by frame in serial. In this paper, a new backprojection algorithm is proposed. The algorithm uses data inside the ...
متن کاملTheoretically exact FBP-type inversion algorithm for spiral CT
| Proposed is a theoretically exact formula for inversion of data obtained by a spiral CT scan with a 2D detector array. The detector array is supposed to be of limited extent in the axial direction. The main property of the formula is that it can be implemented in a truly ltered backprojection fashion. First, one performs shift-invariant ltering of a derivative of the cone beam projections, an...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Computer methods and programs in biomedicine
دوره 98 3 شماره
صفحات -
تاریخ انتشار 2010