Dental implants: early versus standard two-stage loading (animal study).

نویسندگان

  • Mansour Rismanchian
  • Farshad Bajoghli
  • Tabakhian Gholamreza
  • Mohamad Razavi
چکیده

Direct bone formation on the implant surface is a treatment goal in implant dentistry. It was always thought that a healing period of 3 months for the lower jaw and 5-6 months for the upper jaw was required for osseointegration to occur. Recent studies, however, show that with the early loading protocol, osseointegration is possible as well. The goal of this study was to evaluate clinical, histologic, and histomorphometric parameters of implants with early loading protocols and implants that did not undergo the early loading protocol. In this experimental study, the first to the fourth premolar teeth were extracted from the lower jaws of 3 dogs. After a healing period of 3 months, 12 BioHorizons internal implants 4.5 × 10.5 mm were placed in the mandible of the dogs. The implant stability quotient (ISQ) was recorded. After 3 weeks, half of the implants were exposed, and after recording ISQ, polycarbonate crowns were placed on them and occlusion was adjusted so that there was no contact in centric occlusion and no lateral movement with the opposing teeth. After 3 months, the ISQs were recorded for all the implants. Bleeding upon probing and pocket depths were measured for the early loading implants. All the implants were removed using a trephine bur, and cross-sections of 150 μm were prepared, from which the bone implant contact (BIC) and the type of bone around them were obtained. Statistical analysis was conducted with independent t test, paired t test, and repeated analysis of variance. The BIC for the early loaded group was 46.17% ± 12.89%, and for the unloaded group was 44.4% ± 10.45%. This difference was not statistically significant (P = .811). The ISQ for the implants in the early loaded group (before they were removed) was 71 ± 7.35 and that of the unloaded group was 66.75 ± 11.86 .These differences were statistically insignificant. With regard to the result of this study, and the fact that the 2 groups showed no statistically significant differences in a number of major aspects, such as BIC and ISQ, it seems possible to load implants with an earlier than usual protocol with no adverse effects on implant success. It is necessary, however, to follow certain protocols for this type of loading.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical Parameters and Crestal Bone Loss in Internal Versus External Hex Implants at One Year after Loading

Introduction: The survival of an implant system is affected by the choice of antirotational design, which can include an external or internal hex. Implant success also is affected by the maintenance of the crestal bone around implants. The aim of present study was to evaluate the crestal bone loss and clinical parameters related to bone loss in patients loaded with an external or internal hex 3...

متن کامل

Immediate loading in dental implants ( A literature review )

Immediate loading in dental implants ( A literature review ) Dr. Seyedan K.,1 Dr. Hafezeqoran A.,2 Dr. Sazgara H.3 1Assistant Professor, Department of Prosthodentists,Dental School Shahid Beheshti University of Medical Sciences,Tehran, Iran.2Dentist, Post Graduate Student, Department of Prosthodontics, Dental School, Shahid Beheshti University of Medical Sciences, Tehran-Iran.3Associate Profess...

متن کامل

Evaluation of Stability in Short Implants Compared to Standard Implants using Periotest ®: A Pilot Study

Introduction: Among different non-invasive approaches for determining the stability of the implant within the bone is to use a dynamic device called Periotest®.It is designed to provide objective measurement of tooth mobility. The aim of the present study is to evaluate the stress transfer and stability in short and standard dental implants using Periotest®</sup...

متن کامل

Recent advances in dental implants

Dental implants are a common treatment for the loss of teeth. This paper summarizes current knowledge on implant surfaces, immediate loading versus conventional loading, short implants, sinus lifting, and custom implants using three-dimensional printing. Most of the implant surface modifications showed good osseointegration results. Regarding biomolecular coatings, which have been recently deve...

متن کامل

The Risk Factors in Early Failure of Dental Implants: a Retrospective Study

Statement of the Problem Despite the low failure rate of dental implants, recognition of the risk factors can enhance the predictability of failure. Purpose The aim of this study was to evaluate the risk factors for early implant failure. Materials and Method This retrospective cohort study was conducted on two groups of patients, the patients with a failed implant before loading and those ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of oral implantology

دوره 40 1  شماره 

صفحات  -

تاریخ انتشار 2014