Real time endoscopic ultrasound elastography and strain ratio in the diagnosis of solid pancreatic lesions
نویسندگان
چکیده
AIM To evaluate the accuracy of the elastography score combined to the strain ratio in the diagnosis of solid pancreatic lesions (SPL). METHODS A total of 172 patients with SPL identified by endoscopic ultrasound were enrolled in the study to evaluate the efficacy of elastography and strain ratio in differentiating malignant from benign lesions. The semi quantitative score of elastography was represented by the strain ratio method. Two areas were selected, area (A) representing the region of interest and area (B) representing the normal area. Area (B) was then divided by area (A). Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy were calculated by comparing diagnoses made by elastography, strain ratio and final diagnoses. RESULTS SPL were shown to be benign in 49 patients and malignant in 123 patients. Elastography alone had a sensitivity of 99%, a specificity of 63%, and an accuracy of 88%, a PPV of 87% and an NPV of 96%. The best cut-off level of strain ratio to obtain the maximal area under the curve was 7.8 with a sensitivity of 92%, specificity of 77%, PPV of 91%, NPV of 80% and an accuracy of 88%. Another estimated cut off strain ratio level of 3.8 had a higher sensitivity of 99% and NPV of 96%, but with less specificity, PPV and accuracy 53%, 84% and 86%, respectively. Adding both elastography to strain ratio resulted in a sensitivity of 98%, specificity of 77%, PPV of 91%, NPV of 95% and accuracy of 92% for the diagnosis of SPL. CONCLUSION Combining elastography to strain ratio increases the accuracy of the differentiation of benign from malignant SPL.
منابع مشابه
Endoscopic ultrasound elastography for solid pancreatic lesions
Elastography is one of technologies assisting diagnosis of solid pancreatic lesions (SPL). This technology has been previously used for measuring the stiffness of various organs based on a principle of "harder the lesions, higher chance for malignancy". Two elastography techniques; strain and shear wave elastography, are available. For endoscopic ultrasound (EUS), only the former is existing. T...
متن کاملSecond-generation endoscopic ultrasound elastography in the differential diagnosis of solid pancreatic masses. Pancreatic cancer vs. inflammatory mass in chronic pancreatitis.
Endoscopic ultrasonography (EUS) is considered one of the most accurate methods for the diagnosis and staging of pancreatic tumors. EUS-guided fine-needle aspiration (FNA) allows to increase the diagnostic accuracy of EUS in this setting; however, it is technically demanding (a pathologist is also essential) and is furthermore associated with small, but not insignificant morbidity. EUS pancreat...
متن کاملNew endoscopic ultrasonography techniques for pancreaticobiliary diseases
Endoscopic ultrasonography (EUS) is widely used to evaluate pancreaticobiliary diseases, especially pancreatic masses. EUS has a good ability to detect pancreatic masses, but it is not sufficient for the differential diagnosis of various types of lesions. In order to address the limitations of EUS, new techniques have been developed to improve the characterization of the lesions detected by EUS...
متن کاملEndoscopic ultrasound elastography
Endoscopic ultrasound (EUS) elastography is an imaging procedure used for the visualization of tissue elasticity during usual EUS examinations. EUS elastography can be accomplished real-time with state-of-the-art ultrasound systems, with the images being represented in transparent color superimposed on the conventional gray-scale B-mode scans. The aim of this review was to introduce the potenti...
متن کاملEUS elastography for diagnosis of solid pancreatic masses: a meta-analysis.
BACKGROUND The differential diagnosis of solid pancreatic masses has been a significant challenge up until now. EUS elastography is now used as a new technique to distinguish benign from malignant pancreatic masses. However, the sensitivity, specificity, and accuracy are still questionable. OBJECTIVE To evaluate the accuracy of EUS elastography for diagnosis of solid pancreatic masses. DESI...
متن کامل