BACKGROUND AND PURPOSE The use of the conventional temporal bone window for transcranial color-coded duplex sonography (TCCS) often results in difficulties in obtaining angle-corrected flow velocity measurements of the A2 segment of the anterior cerebral artery, the posterior communicating artery, and the midline venous vasculature because of the unfavorable insonation angle. The same applies to B-mode imaging of the frontal parenchyma. However, transorbital TCCS raises problems with the insonation of the orbital lens. To overcome these drawbacks, we studied the feasibility of frontal bone windows for TCCS examinations. METHODS In 75 healthy volunteers (mean age, 45.3+/-17.0 years; age range, 17 to 77 years), the circle of Willis and the venous midline vasculature were insonated through a lateral and paramedian frontal bone window. Insonation quality of parenchymal structures (B-mode) was graded on a 3-point scale depending on the visibility of typical parenchymal landmarks. In a similar manner, the quality of the color-/Doppler-mode imaging of the arteries of the circle of Willis and the internal cerebral veins was assessed. In 15 patients (mean age, 62.7+/-13.7 years; age range, 33 to 83 years), the color-/Doppler-mode imaging quality of the intracranial vessels before and after application of an ultrasound contrast-enhancing agent was compared. RESULTS B-mode insonation quality was optimal to fair in 73.3% of cases using the lateral and in 52.0% of cases using the paramedian frontal bone window, with defined parenchymal structures used as reference. Insonation quality decreased in those older than 60 years. In those younger than 60 years, angle-corrected flow velocity measurements of the A2 segment of the anterior cerebral artery and the internal cerebral vein were possible in 73.6% and 60.0%, respectively. Contrast enhancement resulted in a highly significant improvement in the imaging quality of the intracranial vessels. CONCLUSIONS The transfrontal bone windows offer new possibilities for TCCS examinations, although the insonation quality is inferior to the conventional temporal bone window in terms of failure of an acoustic window. This can be compensated for by application of an ultrasound contrast-enhancing agent.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Consensus recommendations for transcranial color-coded duplex sonography for the assessment of intracranial arteries in clinical trials on acute stroke.

BACKGROUND AND PURPOSE Transcranial color-coded duplex sonography has become a standard diagnostic technique to assess the intracranial arterial status in acute stroke. It is increasingly used for the evaluation of prognosis and the success of revascularization in multicenter trials. The aim of this international consensus procedure was to develop recommendations on the methodology and document...

متن کامل

Assessment of >/=50% and <50% intracranial stenoses by transcranial color-coded duplex sonography.

BACKGROUND AND PURPOSE A favorable risk-benefit ratio for warfarin compared with aspirin has been reported for the prevention of major vascular events in symptomatic >/=50% intracranial stenoses. Transcranial color-coded duplex sonography (TCCS) criteria providing an accurate detection of >/=50% and <50% stenoses of the anterior, middle, and posterior cerebral arteries and basilar and vertebral...

متن کامل

Benefit of echocontrast-enhanced transcranial color-coded duplex ultrasound in the assessment of intracranial collateral pathways.

BACKGROUND AND PURPOSE Although clinically important, proper assessment of intracranial arterial collateral pathways by transcranial color-coded duplex sonography (TCCD) in patients with internal carotid artery (ICA) high-grade stenosis or occlusion is occasionally made difficult by an insufficient temporal bone window, an unfavorable insonation angle, or low flow velocity or volume. In these c...

متن کامل

Transcranial color-coded duplex sonography in cerebral aneurysms.

BACKGROUND AND PURPOSE Diagnosis and successful therapy before rupture of cerebral aneurysms would be most desirable in view of the high mortality and morbidity rates of aneurysmal subarachnoid hemorrhage. Using transcranial color-coded duplex sonography, we studied radiologically proven cerebral aneurysms to define ultrasonographic criteria and sensitivity for their diagnosis and detection. ...

متن کامل

Echo-enhanced transcranial color-coded duplex sonography in the diagnosis of cerebrovascular events: a validation study.

BACKGROUND AND PURPOSE Transcranial color-coded duplex sonography (TCCD) is a diagnostic technique for evaluation of intracranial arteries in patients with acute stroke. Echo-enhancing contrast agents (EEAs) are necessary to visualize intracranial vessels in up to 30% of patients because of limited acoustic bone windows. In this study, we assessed the diagnostic efficacy of echo-enhanced TCCD (...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Stroke

دوره 30 4  شماره 

صفحات  -

تاریخ انتشار 1999