Resting and Postexercise Heart Rate Detection From Fingertip and Facial Photoplethysmography Using a Smartphone Camera: A Validation Study
نویسندگان
چکیده
BACKGROUND Modern smartphones allow measurement of heart rate (HR) by detecting pulsatile photoplethysmographic (PPG) signals with built-in cameras from the fingertips or the face, without physical contact, by extracting subtle beat-to-beat variations of skin color. OBJECTIVE The objective of our study was to evaluate the accuracy of HR measurements at rest and after exercise using a smartphone-based PPG detection app. METHODS A total of 40 healthy participants (20 men; mean age 24.7, SD 5.2 years; von Luschan skin color range 14-27) underwent treadmill exercise using the Bruce protocol. We recorded simultaneous PPG signals for each participant by having them (1) facing the front camera and (2) placing their index fingertip over an iPhone's back camera. We analyzed the PPG signals from the Cardiio-Heart Rate Monitor + 7 Minute Workout (Cardiio) smartphone app for HR measurements compared with a continuous 12-lead electrocardiogram (ECG) as the reference. Recordings of 20 seconds' duration each were acquired at rest, and immediately after moderate- (50%-70% maximum HR) and vigorous- (70%-85% maximum HR) intensity exercise, and repeated successively until return to resting HR. We used Bland-Altman plots to examine agreement between ECG and PPG-estimated HR. The accuracy criterion was root mean square error (RMSE) ≤5 beats/min or ≤10%, whichever was greater, according to the American National Standards Institute/Association for the Advancement of Medical Instrumentation EC-13 standard. RESULTS We analyzed a total of 631 fingertip and 626 facial PPG measurements. Fingertip PPG-estimated HRs were strongly correlated with resting ECG HR (r=.997, RMSE=1.03 beats/min or 1.40%), postmoderate-intensity exercise (r=.994, RMSE=2.15 beats/min or 2.53%), and postvigorous-intensity exercise HR (r=.995, RMSE=2.01 beats/min or 1.93%). The correlation of facial PPG-estimated HR was stronger with resting ECG HR (r=.997, RMSE=1.02 beats/min or 1.44%) than with postmoderate-intensity exercise (r=.982, RMSE=3.68 beats/min or 4.11%) or with postvigorous-intensity exercise (r=.980, RMSE=3.84 beats/min or 3.73%). Bland-Altman plots showed better agreement between ECG and fingertip PPG-estimated HR than between ECG and facial PPG-estimated HR. CONCLUSIONS We found that HR detection by the Cardiio smartphone app was accurate at rest and after moderate- and vigorous-intensity exercise in a healthy young adult sample. Contact-free facial PPG detection is more convenient but is less accurate than finger PPG due to body motion after exercise.
منابع مشابه
Photoplethysmography Signal Analysis for Optimal Region-of-Interest Determination in Video Imaging on a Built-In Smartphone under Different Conditions
Smartphones and tablets are widely used in medical fields, which can improve healthcare and reduce healthcare costs. Many medical applications for smartphones and tablets have already been developed and widely used by both health professionals and patients. Specifically, video recordings of fingertips made using a smartphone camera contain a pulsatile component caused by the cardiac pulse equiv...
متن کاملNovel Fingertip Image-Based Heart Rate Detection Methods for a Smartphone
We hypothesize that our smartphone-based fingertip image-based heart rate detection methods reliably detect the heart rhythm and rate of subjects. We propose fingertip curve line movement-based and fingertip image intensity-based detection methods, which both use the movement of successive fingertip images obtained from smartphone cameras. To investigate the performance of the proposed methods,...
متن کاملAccuracy of Heart Rate Measurement Using Smartphones During Treadmill Exercise in Male Patients With Ischemic Heart Disease
OBJECTIVE To evaluate the accuracy of a smartphone application measuring heart rates (HRs), during an exercise and discussed clinical potential of the smartphone application for cardiac rehabilitation exercise programs. METHODS Patients with heart disease (14 with myocardial infarction, 2 with angina pectoris) were recruited. Exercise protocol was comprised of a resting stage, Bruce stage II,...
متن کاملMulti - Modal Heart - Beat Estimation On an iPhone by Narges Norouzi
Multi-Modal Heart-Beat Estimation On an iPhone Narges Norouzi Master of Applied Science Graduate Department of Electrical and Computer Engineering University of Toronto 2014 Current generation smartphone video cameras and microphones enable photoplethysmography (PPG) and phonocardiography (PCG) acquisition. In this thesis, I utilized the iPhone microphone and camera to measure heart rate. We de...
متن کاملFingertip Pulse Wave (PPG signal) Analysis and Heart Rate Detection
To study heart beat pulse wave propagation in real time and to evaluate the vascular blood flow resistance an important physiological parameter for vascular diagnostics. Photoplethysmography is a non-invasive technique that measures relative blood volume changes in the blood vessels close to the skin. PPG analysis emphasizes the importance of early evaluation of the diseases We present the resu...
متن کامل