OBJECTIVES To compare the biomechanical properties of a new nitinol intramedullary (IM) scaffold implant with those of volar plates for the treatment of dorsally comminuted extra-articular distal radius fractures using an established model. METHODS A dorsal wedge osteotomy was performed on a bone model to simulate a dorsally comminuted extra-articular distal radius fracture. This model was used to compare stiffness of 3 different distal radius fixation devices--an IM scaffold implant, a commercially available titanium volar locking plate, and a stainless steel non-locking T-plate. Six constructs were tested per group. Tolerance for physiological loading was assessed by applying 10,000 cycles of axial loading up to 100 N applied at 2 Hz. Axial and eccentric load stiffness were assessed before cyclic loading and axial stiffness again after cyclic loading. Groups were compared using analysis of variance. RESULTS Initial axial stiffness (in Newton per millimeter) was significantly (P = 0.011) different only between the volar locking plate (427 ± 43) and non-locking T-plate (235 ± 69). After cyclic loading, axial stiffness was not significantly different between the volar locking plate (392 ± 67) and IM scaffold implant (405 ± 108), but both were significantly (P < 0.001) stiffer than the non-locking T-plate (187 ± 53). Eccentric loading stiffness was not significantly different between the IM scaffold implant (67 ± 140) and volar locking plate (63 ± 5), but both were significantly (P < 0.001) stiffer than the non-locking T-plate (25 ± 4). CONCLUSIONS Stiffness of the IM scaffold implant and volar locking plate fracture model constructs was equivalent. Biomechanical testing suggests that this novel IM scaffold provides sufficient stability for clinical use, and further testing is warranted.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of the treatment outcome of closed extra-articular distal tibia fracture: IM nailing vs plating

  Abstract   Background: The tibial diaphyseal fractures are the most common type of long   bone fractures encountered by most orthopedic surgeons. In accordance with descriptive indices of tibia fractures on the basis of their location in the bone, distal tibia   fractures have the second incidence of all tibia fractures after the middle tibia fractures.   The purpose of the study was to asses...

متن کامل

Complications and Plate Removal Surgeries after Performing Volar Plating of Unstable Distal Radius Fractures

Complications have often been reported in the literature after distal radius fractures treated conservatively or operatively [1-3]. Previously, the main indication for volar plating was a volar Barton or Smith fracture, but now volar locking plates are the most commonly used treatment for unstable distal radius fractures and during the last decade this method has become increasingly popular [4]...

متن کامل

Is minimally invasive application by intramedullary osteosynthesis in comparison with volar plating real benefit in the treatment of distal radius fractures?

PURPOSE OF THE STUDY Can minimally invasive intramedullary osteosynthesis of distal radius fractures provide better therapeutic results than multidirectional locking plates. Retrospective study of 68 patients operated for distal radius fractures, 18 were treated with intramedullary X-screw (XSCR) fixation and 50 with the multidirectional angle-stable plate system (APTUS). The evaluation at 1-ye...

متن کامل

Comparison of close reduction and percutaneous pin fixation as treatments for distal metaphyseal radius fractures

Background: Distal radius fractures are one of the most common fractures of skeletal system and because of the aging of population, its incidence is rising. The aim of the present research was to evaluate the close reduction and percutaneous pin fixation as a treatment option. Material and methods: 44 patients who were type 2 according to universal classification or type 2 or 3 according to Ol...

متن کامل

Various volar shapes of the distal radius and its implications on volar plate osteosynthesis

Volar plate fi xation with use of either a locking plate or a neutralization plate has become increasingly popular among surgeons for the treatment of dorsally comminuted distal radial fractures. When doing volar plating of radius fractures, we observed a considerable variation in the morphology of the distal radius. Research in the literature reveals rare information about the anatomic variati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of orthopaedic trauma

دوره 27 9  شماره 

صفحات  -

تاریخ انتشار 2013