Full-foil x-ray mapping of integrated column density applied to the absolute determination of mass attenuation coefficients
نویسندگان
چکیده
Recent measurements of mass attenuation coefficients have identified the determination of the thickness of the absorbing specimen as the major limitation to the accuracy of the measurement. We present a technique for determining the mass attenuation coefficient with high accuracy. The technique uses the integral of the density along a column extending through the thickness of the absorber, which we term the integrated column density. Attenuation measurements mapped across the entire absorber are used to determine a relative map of the integrated column density. These relative measurements are then placed on an absolute scale by comparison with the average integrated column density and are used to determine the mass attenuation coefficient. This approach correctly treats variations in the integrated column density across the foil. We illustrate the technique with an absolute measurement of the x-ray mass attenuation coefficient of molybdenum using a synchrotron beam of energy 41.568 keV ± 0.005 keV. We obtain [ μ ρ ] = 11.6514 cm2 g−1 ± 0.0032 cm2 g−1, accurate to 0.028%—over one order of magnitude more accurate than any previous work. The full-foil technique used to determine the mass attenuation coefficient is used to determine an integrated column density profile of a sample to a precision of around 0.05% of the thickness of the absorber. We demonstrate the sensitivity of the technique by observing a periodic thickness variation of order 0.1 μm occurring over a 5 mm length scale on a nominally 50 μm thick molybdenum foil.
منابع مشابه
An improvement to the full-foil mapping technique for high accuracy measurement of X-ray mass attenuation coefficients
The limiting uncertainty in recent high accuracy measurements of the mass attenuation coefficient is the measurement of the integrated column density. An improvement in the design of the absorption foil holder is described which reduces the integrated column density uncertainty. The new design allows the edges of the foil to be more accurately mapped by the X-ray beam by reducing the largest so...
متن کاملAn iterative method to estimate x-ray attenuation coefficients in computed tomography
Introduction: The basis of image formation in Computed Tomography (CT) lies in the x-ray linear attenuation coefficient of the scanned material. Compton scattering and photoelectric effect are the dominant interactions of the x-ray photons with the subject, in the range of diagnostic radiology. These two coefficients are important in tissue characterization by Dual-Energy CT (D...
متن کاملNew consistency tests for high-accuracy measurements of X-ray mass attenuation coefficients by the X-ray extended-range technique.
An extension of the X-ray extended-range technique is described for measuring X-ray mass attenuation coefficients by introducing absolute measurement of a number of foils - the multiple independent foil technique. Illustrating the technique with the results of measurements for gold in the 38-50 keV energy range, it is shown that its use enables selection of the most uniform and well defined of ...
متن کاملAccurate determination of the thickness or mass per unit area of thin foils and single-crystal wafers for x-ray attenuation measurements
The determination of the local mass per unit area m /A=erdt and the thickness of a specimen is an important aspect of its characterization and is often required for material quality control in fabrication. We discuss common methods which have been used to determine the local thickness of thin specimens. We then propose an x-ray technique which is capable of determining the local thickness and t...
متن کاملInvestigation of the Mass Attenuation Coefficient for Composites Containing Nano and Micro-Particles of Copper Oxide against Diagnostic X-ray
Radiation protection and the selection of suitable materials to reduce radiation effects is one of the important branches of medical science and radiation. In this paper, the mass attenuation coefficients, half value layer thicknesses and thicknesses of 0/5 mm lead of polyvinyl chloride (PVC) composites containing Nano and micro-particles of copper oxide are calculated using experimental method...
متن کامل