Fine-tuning management of the Heart Assist 5 left ventricular assist device with two- and three-dimensional echocardiography
نویسندگان
چکیده
INTRODUCTION Left ventricular assist device (LVAD) implantation is a viable therapy for patients with severe end-stage heart failure, providing effective haemodynamic support and improved quality of life. The Heart Assist 5 (Micromed Cardiovascular Inc, Houston, TX) continuous-flow LVAD has been on the market in Europe since May 2009. METHODS We evaluated nine Heart Assist 5 LVAD patients with two- and three-dimensional transthoracic echocardiographic (TTE) and transoesophageal echocardiographic (TEE) parameters between December 2011 and December 2013. The pre-operative TTE LVAD evaluations included left ventricular (LV) function and structure, quantification of right ventricular (RV) function and tricuspid regurgitation (TR), assessment of aortic and mitral regurgitation, and presence of patent foramen ovale and intra-cardiac clots. Peri-operative TEE determined the inflow cannula and septum position, and assessed the de-airing process while weaning from cardiopulmonary bypass. Post-operative serial follow-up TTE showed the surgical results of LVAD implantation, determined the overall structure and function of the LV, RV and TR, and observed the inflow and outflow cannula position. RESULTS Nine patients who had undergone Heart Assist 5 LVAD implantation and had been followed up for more than 30 days were included in this study. Eight patients had ischaemic cardiomyopathy and one had adriamycin-induced cardiomyopathy. Pre-implantation data: the mean age of the patients was 52 ± 13 (34-64) years, mean body surface area (BSA) was 1.8 ± 0.2 (1.6-2.0) m2, mean cardiac index (CI) was 2.04 ± 0.4 (1.5-2.6) l/min/m2, mean cardiac output (CO) was 3.7 ± 0.7 (2.6-4.2) l/min, mean ejection fraction (EF) was 23 ± 5 (18-28)%, and right ventricular fractional area contraction (RVFAC) was 43 ± 9 (35-55)%. One patient had aortic valve replacement (AVR) during the LVAD implantation, and excess current alarms and increased power were suspected to be caused by a possible thrombus. Close follow up with TTE studies were carried out to clear the LV of thrombus formation, and the inflow cannula position was checked to maintain the septum in the midline, so preventing the suction cascade. Four patients were followed up for more than two years, and two were followed up for more than a year. Three patients died due to multi-organ failure. Follow-up speed-change TTE studies of six patients showed that the mean speed was 9 800 ± 600 (9 500-10 400) rpm, and mean CO was 4.7 ± 0.3 (4.3-5.0) l/min during the three-month post-implant period. CONCLUSION We believe that TTE can play a major role in managing LVAD patients to achieve optimal settings for each patient. A large series is mandatory for assessment of echocardiographic studies on Heart Assist 5 LVAD.
منابع مشابه
Design an Equivalent Left Ventricular Assist Device for Medical Equipment Labs
LVAD is a mechanical pump supporting a weak heart function and blood flow. Sometimes, the heart may not recover fast enough to take over the pumping action immediately after surgery, in such patients a temporary support device has been employed to maintain the pumping action until the patient’s own heart recovers. This device can be considered as a temporary alternative before the process of ar...
متن کاملImprovement of Left Ventricular Assist Device (LVAD) in Artificial Heart Using Particle Swarm Optimization
In this approach, the Left ventricular assist pump for patients with left ventricular failure isused. The failure of the left ventricle is the most common heart disease during these days. Inthis article, a State feedback controller method is used to optimize the efficiency of a samplingpump current. Particle Swarm Algorithm, which is a set of rules to update the position andvelocity, is applied...
متن کاملTreatment options for patients with mobile left ventricular thrombus and ventricular dysfunction: a case series
INTRODUCTION Little is known about the optimal management of large, mobile, pedunculated left ventricular clots. The management is particularly challenging in patients with advanced heart failure considered for left ventricular assist device implantation, because the clot may cause pump thrombosis. METHODS We retrospectively reviewed the records of patients with left ventricular thrombi ident...
متن کاملApplication of centrifugal pump in right ventricular failure due to pulmonary artery hypertension. (A case report)
Background: It has not been yet developed a ost suitable method to treat right ventricular failure due to pulmonar artery hypertention resulted from ventricular arrhythia. Though some case reports about patients ready to heart transplant using left assist device or biventral assist device as bridge have been published in Journals, but nocase concerning application of centrifugal pump for treatm...
متن کاملPeri-Operative Care Following Left Ventricular Assist Device Implantation and Heart Transplantation
Abbreviations: TEE: Trans esophageal Echocardiography; HF: Heart Failure; HT: Heart Transplantation; LVAD: Left Ventricular Assist Device; ESHF: End Stage Heart Failure; LVHF: Left Ventricular Heart Failure; LV: Left Ventricular; LVEDV: Left Ventricular End Diastolic Volume; PV: Prolonged Ventilation; BNP: B-Type Natriuretic Peptide; VAD: Ventricular Assist Device; LVEDP: Left Ventricular End D...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 27 شماره
صفحات -
تاریخ انتشار 2016