Effects of sample aging on total cholesterol values determined by the automated ferric chloride-sulfuric acid and Liebermann-Burchard procedures.

نویسندگان

  • P D Wood
  • P S Bachorik
  • J J Albers
  • C C Stewart
  • C Winn
  • K Lippel
چکیده

To investigate the comparability of three commonly used methods for determination of total cholesterol in plasma in several studies, we used fresh plasma samples as well as plasmas and reference sera that had been stored frozen at -15 degrees C for as long as several years. Duplicate determinations by the manual method of Abell et al. (J. Biol. Chem. 195: 357, 1952) were compared with estimates from one to five continuous-flow analyzers by the ferric chloride-sulfuric acid procedure and also with estimates from five to 13 continuous-flow analyzers by the Liebermann-Burchard procedure with calibrator, as part of the laboratory standardization activities of the Lipid Research Clinics. The agreement among all three procedures was generally within acceptable limits (within 5% of the manual method) when plasmas or sera were fresh or had been frozen for less than one month. Results by the manual method of Abell et al. agreed well with those by the automated Liebermann-Burchard method for samples that had been stored at -15 degrees C for as long as two years. However, the automated ferric chloride-sulfuric acid procedure often showed unacceptably high values (as compared with those from the manual method) for samples that had been stored frozen for a year or more. With the ferric chloride-sulfuric acid method, measured cholesterol concentration increased about 2.5% per year of storage for at least two years. We conclude that reference sera of plasmas that have been kept in long-term frozen storage (-15 degrees C) are not suitable for ongoing standardization of the automated ferric chloride-sulfuric acid assay for cholesterol.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of ferric ammonium sulfate in serum cholesterol determination.

To determine cholesterolin biologicalfluids,use of the ferric chloride-sulfuric acid reagent introduced by Zlatkis et al. (1) is relatively simple and reliable (2, 3), and the sensitivityof the reagent for cholesterol is four to five times greater than that of the Liebermann-Burchard reagent (2). However, Parekh and Jung (4) reported that hydrogen chloride is evolved during the ferric chloride-...

متن کامل

A comparison of methods for the estimation of serum cholesterol and values in random samples of populations in the 55-64 age group.

The increasing mortality from coronary heart disease has focused attention on its epidemiological and biological aspects, and in the latter connexion much work has been done on the relationship between blood cholesterol levels and heart disease. As a result many methods for the estimation of cholesterol levels in serum have been published and their multiplicity indicates the difficulties of the...

متن کامل

Method for fully automated determination of total cholesterol in blood serum, including saponification and extraction.

A fully automated method has been developed for the determination of total cholesterol in blood serum, using the AutoAnalyzer system. According to the new method, based on the cholesterol determination of Abell et a!. (1), the serum sample is saponified and subsequently extracted with carbon tetrachloride. After treatment with Liebermann-Burchard reagent, the amount of cholesterol is determined...

متن کامل

Determination of free and total cholesterol by direct chloroform extraction.

Since the Liebermann-Burchard reaction was adopted by Grigaut (1) for the quantitative determination of serum total cholesterol, many modified procedures of the original method have been made. The various procedures have differed in extraction method and in the reagents used in the color development. The separation of cholesterol from its esters with digitonin has had limited application becaus...

متن کامل

Effect of bilirubin and lipemia on an automated method for serum cholesterol.

A simple automated procedure for total serum cholesterol, employing a stable Liebermann-Burchard reagent, was tested. The method has good precision, and results agree well with extraction methods for total cholesterol on normal serums. Serum samples with elevated bilirubin levels gave cholesterol values which were too high and which could not always be corrected for. Lipemic serums in some inst...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 26 5  شماره 

صفحات  -

تاریخ انتشار 1980