In vitro study of esomeprazole sachet suspension administered via enteral feeding tubes.

نویسندگان

  • Paul Stewart
  • Natalie Dayneka
  • Sylvain Grenier
  • Carolyn Stewart
  • Lise Beadow
  • Gerry Joseph
  • David Mack
  • Régis Vaillancourt
چکیده

Administration of drugs through enteral feeding tubes can be a simple way by which infants and children can receive medications, but it introduces concerns about potential blockage of the tube. The risk of feeding tubes becoming blocked is greater with small-diameter feeding tubes and low flush volumes.Tube blockage is disruptive to patient care, and replacing tubes can be uncomfortable for the children. Patients with enteral feeding tubes may require acid suppression with proton pump inhibitors (PPIs). Previous studies have assessed the delivery of a single PPI dose through feeding tubes, with delivery of esomeprazole typically being less labour-intensive and more complete than delivery of omeprazole and lansoprazole. However, these studies did not evaluate the potential for blockage with repeated administration of PPIs. This is a real concern, as the tubes may be in place for up to several months. A new sachet formulation of esomeprazole (Nexium), developed for people who have difficulty swallowing capsules, can be administered by enteral feeding tube. With the small diameter of the esomeprazole pellets and the formation of a viscous suspension after reconstitution, this formulation was designed to remain stable in solution and to prevent clogging within enteral tubes. The objective of our in vitro study was to evaluate the potential for clogging (and the resulting change in feeding flow rate) with repeated delivery of 10-mg esomeprazole sachet as suspension through the smalldiameter enteral feeding tubes used at the Children’s Hospital of Eastern Ontario and to assess the use of these tubes to deliver the suspension. Three different types of enteral feeding tubes, each of a different size, were tested: size 6 French Pedi-Tube (Kendall, Mansfield, Massachusetts), size 8.5 French Dawson-Mueller drainage catheter (Cook Canada Inc, Stouffville, Ontario), and size 10 French urological catheter (Bard Canada Inc, Mississauga, Ontario). Four tubes of each type were tested, for a total of 12 tubes. Each tube received a continuous feed of Enfamil A+ formula (Mead Johnson Nutrition, Ottawa, Ontario) at 25 mL/h for 7 consecutive days, with an average of 2 h downtime per day for maintenance and drug administration. For each tube, the formula was delivered by a Kangaroo ePump (Kendall; total of 12 pumps), by means of the pump’s compatible 500-mL feed bag set. Each tube was positioned vertically and emptied into its own graduated bottle. For each tube type, 3 of the 4 tubes received the drug suspension; the fourth tube received water as a control. Every 12 h the pumps were halted to allow measurement of volumes delivered, replenishment of formula, and administration of the esomeprazole suspensions. With the pumps on hold, the volume that had been fed through each tube was measured (using the respective graduated bottle) and recorded. The predicted volume fed, as displayed on each pump, was also recorded. The exterior of each tube was rinsed with warm water. The feed remaining in the bag sets was discarded, and the feed bags were rinsed with hot water and refilled with 310 mL of formula. The 10-mg esomeprazole sachets were mixed according to manufacturer’s guidelines in 15 mL sterile water. The tubes were disconnected from the feed lines one at a time, and the drug suspension or placebo was delivered with a 30-mL syringe. The drug infusion time was the same for each tube (4 or 5 s). The additional flush of 15 mL advised by the manufacturer’s guidelines was not used, so as to simulate drug administration for a patient with volume restriction. Each tube received a 5-mL flush with sterile water before and after delivery of drug or placebo. After drug administration, the tube was reconnected and the pump restarted. The stop, start, and drug administration times were recorded individually for each pump or tube. Blockage of the 12 enteral feeding tubes was assessed by measurement of the feed flow rate. Average flow rates were calculated according to the volume delivered for a 12-h period. A change in the calculated feed flow rate was considered significant if it was outside the ±10% operating range. The pumps had the capacity to sound an alert when a blockage occurred. If this happened, the tube was removed and was not replaced. The bag set was restarted and run for a short period (30 min) to confirm that the blockage was in the tube and not the bag set. On the sixth day of continuous feeding with twice-daily drug administration, one complete block occurred immediately after administration of the 11th dose of esomeprazole into 1 of the 3 size 6 French tubes receiving the drug suspension. There was no observable change in the feed flow rate leading up to the blockage in this tube. The only indication of a potential blockage occurred during the final drug administration, when it was more difficult than usual (i.e., more pressure on the syringe was required) to administer the drug through the tube. No blockages occurred in any of the other tubes, and there were no observable changes in feed rates in any of the 3 tube types tested. Administration of the viscous suspension through the size 6 French tubes required significant pressure on the syringe. Using the dual-port design on these tubes to deliver the drug suspension without detaching the tube resulted in backflow of drug into the feed bag set. When the tube was detached from the bag set to prevent backflow during drug administration, minor leaks from the dual port occurred. On the basis of the data from this study, we conclude that the potential for blockage exists when esomeprazole sachet as suspension is delivered through size 6 French feeding tubes. However, there were no changes in feed flow rates until complete failure (blockage) of the feeding tube occurred. The other tubes tested showed no signs of blockage or changes in feed flow rate.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Administration of proton pump inhibitors in patients requiring enteral nutrition.

further complicated by the fact that unless the PPI molecule is protected, it is subject to degradation in the presence of stomach acid.3 The PPIs (except for Zegerid) are therefore encapsulated or enterically coated to prevent premature activation of the drug in the presence of gastric acid.2,3 Opening the capsule and administering the contents have the potential to leave the granules vulnerab...

متن کامل

In Vitro Evaluation of Eslicarbazepine Delivery via Enteral Feeding Tubes.

Purpose: The feasibility of preparing an eslicarbazepine acetate suspension using Aptiom tablets for administration via enteral feeding tubes was evaluated. Methods: Eslicarbazepine acetate suspension (40 mg/mL) was prepared using Aptiom tablets after optimizing the tablet crushing methods and the vehicle composition. A stability-indicating high-performance liquid chromatography (HPLC) method w...

متن کامل

Delivery of esomeprazole magnesium through nasogastric and gastrostomy tubes using an oral liquid vehicle as a suspending agent in vitro.

PURPOSE The optimal delivery medium for esomeprazole magnesium enteric-coated pellets dispersed in various concentrations of Ora-Plus suspension through commonly used nasogastric and gastrostomy tubes using a previously used standardized in vitro protocol was studied. METHODS The study was conducted in two phases. In phase A, 60 size 14 French nasogastric tubes were used to compare esomeprazo...

متن کامل

Medication administration through enteral feeding tubes.

PURPOSE An overview of enteral feeding tubes, drug administration techniques, considerations for dosage form selection, common drug interactions with enteral formulas, and methods to minimize tube occlusion is given. SUMMARY Enteral nutrition through a feeding tube is the preferred method of nutrition support in patients who have a functioning gastrointestinal tract but who are unable to be f...

متن کامل

The administration of drugs via enteral feeding tubes.

The practice of administering drugs via enteral feeding tubes has become complex. The range of enteral feeding tubes and medicines has increased dramatically in recent years and this has led to a gap between clinical practice and best practice.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Canadian journal of hospital pharmacy

دوره 62 1  شماره 

صفحات  -

تاریخ انتشار 2009