Adrenal status in children with septic shock using low-dose stimulation test.
نویسندگان
چکیده
OBJECTIVES There is paucity of data on the magnitude of absolute or relative adrenal insufficiency in septic shock, especially in children. We conducted a prospective study to determine the prevalence of adrenal insufficiency in children with septic shock using a low-dose Synacthen (1 microg) stimulation test. DESIGN Cross-sectional study. SETTING Pediatric intensive care unit in a tertiary care hospital in northern India. PATIENTS Children with septic shock. INTERVENTIONS None. MEASUREMENTS AND MAIN RESULTS We performed cortisol estimation at baseline and after low-dose Synacthen (1 microg) stimulation at 30 and 60 mins in children with fluid refractory septic shock admitted to our pediatric intensive care unit. Basal cortisol levels <7 microg/dL and peak cortisol level <18 microg/dL were used to define adrenal insufficiency. An increment of <9 microg/dL after stimulation was used to diagnose relative adrenal insufficiency. As there is lack of consensus on the cutoffs for defining relative adrenal insufficiency using the low-dose adrenocorticotropic hormone test, we evaluated different cutoff values (increment at 30 mins, increment at 60 mins, greater of the two increments) and evaluated their association with the incidence of catecholamine refractory shock and outcomes. Children with sepsis but without septic shock were sampled for baseline cortisol levels as a comparison. Thirty children (15 girls) with septic shock were included; median age (95% confidence interval) was 36.5 (9.39- 58.45) months. Median Pediatric Risk of Mortality score was 22.5 (14.13-24.87). Fifteen (50%) children survived. The median (95% confidence interval) cortisol values at baseline and 30 mins and 60 mins after stimulation were 71 (48.74-120.23) microg/dL, 78.1 (56.9-138.15) microg/dL, and 91 (56.17-166.44) microg/dL, respectively. The median baseline cortisol value in age- and gender-matched children with sepsis was 11.5 microg/dL. None of the children with septic shock fulfilled the criteria for absolute adrenal insufficiency. However, nine (30%) patients had relative adrenal insufficiency (increment in cortisol <9 microg/dL). Of these nine patients, five (56%) died; of the 21 patients with a greater increment in cortisol after stimulation, ten died (p = .69). Compared with patients in septic shock with normal adrenal reserve, those with relative adrenal insufficiency had a higher incidence of catecholamine refractory shock (p = .019) but no difference in mortality rate (p = .69). On the sensitivity and specificity analysis using various cutoffs of increment, the best discrimination for catecholamine refractory shock was obtained with a peak increment <6 microg/dL. CONCLUSIONS Relative adrenal insufficiency is common in children with septic shock and is associated with catecholamine refractory shock.
منابع مشابه
Adrenal function in sepsis and septic shock.
OBJECTIVE To review diagnostic criteria and treatment of adrenal insufficiency in pediatric patients with severe sepsis and septic shock. SOURCES Articles were selected using MEDLINE (1966-June 2007), Embase (1994-2007) and Cochrane Library (2000-2007) databases. following key words were utilized: septic shock, sepsis, corticosteroids, adrenal insufficiency and children. SUMMARY OF THE FIND...
متن کامل[Adrenal insufficiency in children with septic shock].
OBJECTIVE To review the criteria for diagnosing and treating adrenal insufficiency in patients with septic shock. SOURCE OF DATA Articles published in Brazilian and foreign journals selected through these publicationś websites and Medline, as well as references cited in key articles. SUMMARY OF THE FINDINGS The literature reports a range betwen 17 and 54% for the finding of adrenal insuffic...
متن کاملThe effect of physiologic dose of intravenous hydrocortisone in patients with refractory septic shock: a randomized control trial
Objective: Septic shock is a response to infection and tissue hypoperfusion which does not respond to fluid therapy and eventually leads to organ dysfunction. Aggressive treatment of a broad-spectrum antimicrobial and supportive measures are the cornerstones of successful treatment. In addition to the main treatment, there are adjunctive therapies. Steroids are one of the treat...
متن کاملAdrenal insuYciency in septic shock
Background—Functional adrenal insuYciency has been documented in critically ill adults. Objective—To document the incidence of adrenal insuYciency in children with septic shock, and to evaluate its eVect on catecholamine requirements, duration of intensive care, and mortality. Setting—Sixteen-bed paediatric intensive care unit in a university hospital. Methods—Thirty three children with septic ...
متن کاملAdrenal insufficiency during septic shock.
OBJECTIVE To determine whether a baseline (random) cortisol concentration <25 microg/dL in patients with septic shock was a better discriminator of adrenal insufficiency than the standard (250 microg) and the low-dose (1 microg) corticotropin stimulation tests as assessed by the hemodynamic response to steroid replacement. SETTING Intensive care unit. PATIENTS Fifty-nine patients with septi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies
دوره 8 1 شماره
صفحات -
تاریخ انتشار 2007