Effect of impaction sequence on osteochondral graft damage: the role of repeated and varying loads.

نویسندگان

  • Richard W Kang
  • Nicole A Friel
  • James M Williams
  • Brian J Cole
  • Markus A Wimmer
چکیده

BACKGROUND Osteochondral autografts and allografts require mechanical force for proper graft placement into the defect site; however, impaction compromises the tissue. This study aimed to determine the effect of impaction force and number of hits to seat the graft on cartilage integrity. HYPOTHESIS Under constant impulse conditions, higher impaction load magnitudes are more detrimental to cell viability, matrix integrity, and collagen network organization and will result in proteoglycan loss and nitric oxide release. STUDY DESIGN Controlled laboratory study. METHODS Osteochondral explants, harvested from fresh bovine trochleae, were exposed to a series of consistent impact loads delivered by a pneumatically driven device. Each plug received the same overall impulse of 7 Ns, reflecting the mean of 23 clinically inserted plugs. Impaction loads of 37.5 N, 75 N, 150 N, and 300 N were matched with 74, 37, 21, and 11 hits, respectively. After impaction, the plugs were harvested, and cartilage was analyzed for cell viability, histology by safranin-O and picrosirius red staining, and release of sulfated glycosaminoglycans (GAGs) and nitric oxide. Data were compared with nonimpacted controls. RESULTS Impacted plugs had significantly lower cell viability than nonimpacted plugs. A dose-response relationship in loss of cell viability with respect to load magnitude was seen immediately and after 4 days but lost after 8 days. Histological analysis revealed intact cartilage surface in all samples (loaded or control), with loaded samples showing alterations in birefringence. While the sulfated GAG release was similar across varying impaction loads, release of nitric oxide increased with increasing impaction magnitudes and time. CONCLUSION Impaction loading parameters have a direct effect on the time course of the viability of the cartilage in the graft tissue. CLINICAL RELEVANCE Optimal loading parameters for surgical impaction of osteochondral grafts are those with lower load magnitudes and a greater number of hits to ensure proper fit.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Autogenous Osteochondral Transplantation Mosaicplasty (An Animal Study on Sheep)

Background: Autogenous osteochondral grafting of articular defect in weight-bearing surface of large joints has proven to be a proper biomechanical and physiological solution for localized full-thickness defects.Objective: To study the gross and histopathological results of mosaicplasty in an animal model (sheep’s medial femoral condyle), evaluating the factors of defect and graft size, assessi...

متن کامل

Osteochondral Tissue Cell Viability Is Affected by Total Impulse during Impaction Grafting

OBJECTIVE Osteochondral graft transplantation has garnered significant attention because of its ability to replace the lesion with true hyaline cartilage. However, surgical impaction of the graft to anchor it into the defect site can be traumatic and lead to cell death and cartilage degeneration. This study aimed to test the hypothesis that increasing impulse magnitude during impaction of osteo...

متن کامل

Chondrocyte damage following osteochondral grafting using metal and plastic punches: comparative study in an animal model.

PURPOSE Osteochondral impaction grafting to manage isolated chondral defects in femoral condyles usually uses a metal punch to impact the grafts into predrilled cavities. Damage to the chondrocytes during impaction is a concern, however, and new methods are being sought to minimise the damage. We studied if impaction with a plastic punch instead of a metal punch reduces the extent of chondrocyt...

متن کامل

Effect of vibration on the shear strength of impacted bone graft in revision hip surgery.

We developed a method of applying vibration to the impaction bone grafting process and assessed its effect on the mechanical properties of the impacted graft. Washed morsellised bovine femoral heads were impacted into shear test rings. A range of frequencies of vibration was tested, as measured using an accelerometer housed in a vibration chamber. Each shear test was repeated at four different ...

متن کامل

Autogenous Osteochondral Grafting for Treatment of Knee Osteochondritis Dissecans: A Case Series Study

Background: Although some surgical techniques have been described for the operative treatment of unstableOsteochondritis dissecans (OCD) of the knee, outcomes are variable and are not satisfying totally. The aim of thepresent study is to evaluate the outcomes of autogenous osteochondral grafting for OCD of the knee.Methods: In a case series study, from June 2014 to July 2015, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The American journal of sports medicine

دوره 38 1  شماره 

صفحات  -

تاریخ انتشار 2010