18F Protection Issues: Human and -Camera Considerations

نویسندگان

  • ZongJian Cao
  • James H. Corley
چکیده

Objective: Two main issues in protecting radiation workers and the general public from 18F radiation—distance from and lead shielding for an 18F source—were investigated. We also examined the effect of an 18F source on the counting rate of a neighboring -camera. Methods: The dose rates of an 18F vial and a water-filled cylinder were measured using an ionization chamber at different distances with or without lead shielding. In addition, the counting rates of -cameras in the presence of the 18F cylinder were measured with different detector orientations, distances, and energy windows. Results: The dose rate of a point or an extended source in air was proportional to the inverse square of the distance from the source. At 2 m, the dose rate for a 370-MBq 18F source was less than 20 Gy in any single hour, which is the limit for unrestricted areas. The dose rate with 0.318cm-thick lead shielding decreased to about 60%, and that with 5.08-cm-thick lead shielding decreased to about 4%; these rates were higher than those estimated using the narrow-beam attenuation formula. The scattered photons and characteristic x-rays from the lead brick and surrounding structures may have contributed to this result. The decrease in dose rate resulting from a 33% increase in distance was similar to the effect from shielding the source with 0.318-cm-thick lead. At 3 m from a 185-MBq 18F source, the counting rate in the 99mTc window of an Orbiter camera was about 120,000/min when the detector faced the source. This rate was comparable to that of a typical 99mTc clinical study ( 200,000/min). Only when the distance was increased to 11 m and the detector did not face the source did the counting rate decrease to the background level (3,234/min). The counting rate also depended on the energy window of the -camera. On a Vertex camera, the counting rate of 18F in the 99mTc window versus that in the 201Tl (or 67Ga) window was 1:1.7 (or 1:2.7). Conclusion: 18F dose rate can be significantly reduced with distance. Lead shielding is not as effective as was predicted. 18F sources should be kept substantial distances away from -cameras to avoid contamination of image quality.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

CLINICAL INVESTIGATIONS Combined Functional and Structural Evaluation of Cancer Patients with a Hybrid Camera–Based PET/CT System Using 18F-FDG

Correct diagnosis and definition of the functional and anatomic status of lesions in cancer patients are of clinical importance. The value of hybrid imaging using a gamma camera–based PET/CT and 18F-FDG in determining the relationship between mass and cancer was assessed. Methods: Hybrid imaging was performed using a device combining low-dose CT and gamma camera–based PET. Ninety-one patients w...

متن کامل

Behavioral Considerations in Developing Web Information Systems: User-centered Design Agenda

The current paper explores designing a web information retrieval system regarding the searching behavior of users in real and everyday life. Designing an information system that is closely linked to human behavior is equally important for providers and the end users.  From an Information Science point of view, four approaches in designing information retrieval systems were identified as system-...

متن کامل

Securing Embedded Smart Cameras with Trusted Computing

Camera systems are used in many applications including video surveillance for crime prevention and investigation, traffic monitoring on highways or building monitoring and automation. With the shift from analog towards digital systems, the capabilities of cameras are constantly increasing. Today’s smart camera systems come with considerable computing power, large memory, and wired or wireless c...

متن کامل

Do ethical considerations influence any in HTA reports? A review of reports

Background: Dealing with ethical considerations is a major component of Health Technology Assessment (HTA) definitions. Objectives: Present study aimed to explore and describe the manner of ethical analyses in HTA reports and the effects it had on HTA-related decision making around the world.   Methods: By considering the contextual milieu of reports and searching for ethical themes ...

متن کامل

Synthesis of Polypyrrole/CeO2 Nanocomposite and its Application for Improving the Corrosion Protection of Acrylic Waterborne Coating on Mild Steel

In this work, polypyrrole/CeO2 nanocomposite (NC) was synthesized in the presence of methylorange as a reactive self-degraded soft template. The field emission scanning electron microscopy(FESEM) images indicate that the CeO2 NPs have a nucleus effect and cause a homogenous PPycore–shell type morphology with an encapsulation of the CeO2 core by the PPy shell. The effect ofNC on acrylic waterbor...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003